Relation between Teeth-dose and Effective Dose for External Photon Exposure

نویسندگان

  • F. Takahashi
  • Y.Yamaguchi
  • M. Iwasaki
  • C. Miyazawa
  • T. Hamada
چکیده

INTRODUCTION Electron spin resonance (ESR) dosimetry using dental enamel is expected to be applicable to individual dose assessments, in the case where no dose information can be obtained from dosimeters, such as radiation accident. This method is based on the assumption of the linear relation between intensity of ESR signal induced by CO3 radicals and the absorbed dose in dental enamel. The ESR signal has been related to the dose accumulated in teeth for external photon irradiation. Since the hydroxypatite crystal in the dental can easily trap free electrons in the defects in the crystal lattice and the signal in exposed dental enamel remains stable for a long time, ESR dosimetry using dental enamel has been applied to retrospective dose assessments in atomicbomb survivors, residents affected by the Chernobyl accident and accumulated individual doses of workers in Russian nuclear facility “Mayak”. The ultimate quantity is organ or tissue dose and effective dose, risk-weighted average of organ doses over a whole body for an estimation of individual dose. In this context, the retrospective dose assessment by ESR measurement requires a quantitative relationship between the effective dose and the dose in teeth. In this work, Monte Carlo calculations and experiments with a realistic head phantom were carried out to correlate quantitatively dose in teeth with effective dose for external photon exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators

Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isoce...

متن کامل

The Impact of Nano-Sized Gold Particles on the Target Dose Enhancement Based on Photon Beams Using by Monte Carlo Method

Objective(s): In this study we evaluate the impact of the different aspects of Gold Nano-Particles (GNPs) on the target absorptive Dose Enhancement Factor (DEF) during external targeted radiotherapy with photon beams ranging from kilovolt to megavolt energies using Monte Carlo simulation. Methods: We have simulated the interaction of photon beams wi...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

Staff exposure rate in Mahallat hot spring region

Background: High level radiation areas have been recognized on various parts of the earth. Mahallat hot spring region is one of these areas. Study of exposure in these areas can be helpful in investigating the effects of ionizing radiation. Internal and external exposure to the staff was studied. Materials and Methods: Used materials and instruments include: RSS-112 ionizing chamber fo...

متن کامل

Depth dose enhancement in the presence of silicone gel breast prosthesis

Background: External beam radiation therapy is often administered to patients implanted with silicone gel breast prosthesis. The aim of this study was to investigate the influence of silicone gel breast prosthesis on photon dose distributions. In the event of recurrence, the oncologist may be forced to irradiate through the prosthetic device. To quantify the dose enhancement or reduction below ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000