Transcranial Doppler monitoring of transcervical carotid stenting with flow reversal protection: a novel carotid revascularization technique.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Transfemoral carotid stenting, despite becoming very frequent, has some limitations such as difficult groin access in few patients, lack of distal protection during filter placement, or embolization despite protection. Transcervical stenting (TCS) is a novel technique during which a common carotid to jugular vein shunt is placed creating a protective reversal flow in the internal carotid artery after proximal common carotid artery (CCA) clamping. We aim to study, with transcranial Doppler (TCD), cerebral flow changes and microemboli detection during transcervical stenting. METHODS From September 2005 to March 2006, of 65 consecutive patients eligible for carotid revascularization, 23 were considered high risk (sapphire criteria) and underwent TCS. Neurologic examination was performed before and after the procedure by a neurologist and a preprocedure vascular reactivity TCD examination was done in all patients. RESULTS After CCA clamping, flow inversion was observed in the anterior cerebral artery, supplying blood to the middle cerebral artery (MCA) and internal carotid artery (reversal). TCD did not detect any air/solid emboli during stent deployment and angioplasty confirming the reversal flow protection hypothesis. Mean reversal flow time was 15.4 minutes; in all cases, substantial MCA flow was present during CCA clamping (initial mean velocity 30 cm/s), and a slow gradual increase was observed traducing collateral flow recruitment (mean velocity after 5 minutes 36 cm/s, P<0.001). Flow increase was observed in all patients except in those with preprocedural exhausted ipsilateral vascular reactivity (16% versus 2%, P=0.036). The only in-procedure complication was one transient ischemic attack. After CCA unclamping, normal antegrade flow was restored in anterior cerebral artery and mean final MCA velocity increased 16% according to preprocedure flow. CONCLUSIONS TCS with protective internal carotid artery flow reversal can eliminate showers of micoremboli during stent deployment making it a promising carotid revascularization technique in high-risk patients with carotid stenosis.
منابع مشابه
Perioperative Embolization Load and S-100β Do Not Predict Cognitive Outcome after Carotid Revascularization.
BACKGROUND Cognitive changes after carotid revascularization have been reported in 10-20% of patients. The etiology of cognitive impairments remains largely unknown. This study evaluates the predictive value of S-100β serum values and perioperative microembolization on cognition after carotid revascularization. METHODS Forty-six patients with significant carotid stenosis underwent carotid end...
متن کاملANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملPostprocedural emboli in carotid artery stenting: where do they come from?
Stenting: Where Do They Come From? To the Editor: We read with great interest the study by Sztriha et al1 evaluating the early clinical outcome in a large sample of unprotected carotid artery stenting procedures. Although randomized studies comparing endovascular treatment with endarterectomy are showing encouraging results in favor of the endovascular approach,2,3 cerebrovascular complications...
متن کاملA prospective evaluation of cerebral infarction following transcervical carotid stenting with carotid flow reversal.
OBJECTIVE Cerebral embolisation constitutes the main source of complications during transfemoral carotid artery stenting (CAS) and is associated with a high incidence of silent brain infarction. The goal of this study is to evaluate the incidence of new ischaemic cerebral lesions following transcervical CAS with carotid flow reversal for neuroprotection. MATERIALS AND METHODS Thirty-one conse...
متن کاملProtecting the brain:how do we measure success?
The rationale for carotid revascularization, surgical or interventional, is to reduce the patient’s future risk of stroke. Unfortunately, carotid revascularization itself poses a risk of stroke, and enormous efforts have been made in refining both surgical and interventional techniques to reduce periprocedural stroke risk. The incidence of stroke during carotid endarterectomy (CEA) has been red...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 37 11 شماره
صفحات -
تاریخ انتشار 2006