Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

نویسنده

  • Anne M Gillis
چکیده

The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of changes in ventricular activation on cardiac haemodynamics in man. Comparison of right ventricular, left ventricular, and simultaneous pacing of both ventricles.

To investigate the influence of changes in activation on left ventricular ejection, the effects of right ventricular, left ventricular, and simultaneous pacing of both ventricles were studied in 6 patients immediately after replacement of the aortic valve with a Starr-Edwards prosthesis. Variation in pacing site caused little or no change in systemic arterial pressure or cardiac output. However...

متن کامل

Biventricular pacing in patients with bradycardia and normal ejection fraction.

BACKGROUND Observational studies suggest that conventional right ventricular apical pacing may have a deleterious effect on left ventricular function. In this study, we examined whether biventricular pacing is superior to right ventricular apical pacing in preventing deterioration of left ventricular systolic function and cardiac remodeling in patients with bradycardia and a normal ejection fra...

متن کامل

Alternate site pacing in patients at risk for heart failure.

Cardiac pacing from the right ventricular apex is the most common site of cardiac pacing. During the last decade, several studies demonstrated the harmful effects of the iatrogenic left bundle branch block, which is observed in cardiac pacing from the right ventricular apex. These observations led to an interest in alternative right ventricular pacing sites aiming to achieve a more "physiologic...

متن کامل

Non-invasive Determination of the Optimized Atrioventricular Delay in Patients with Implanted Biventricular Pacing Devices

BACKGROUND Biventricular (BiV) is extensively used in the treatment of congestive heart failure but so far no recommendations for optimized programming of atrioventricular-delay (AVD) settings have been proposed. Can AVD optimization be performed using a simple formula based on non-invasive doppler-echocardiography? METHODS 25 patients (ejection fraction 30+/-8%) received BiV ICDs. Doppler-ec...

متن کامل

Left ventricular versus biventricular for cardiac resynchronization therapy: comparable but not equal.

The primary mechanism of benefit associated with cardiac resynchronization therapy (CRT) is attributed to improvement in left ventricular (LV) function resulting from restoration of LV contractile synchrony.1,2 The vast majority of implanted CRT-capable devices are programmed to provide the therapy by simultaneous pacing of the right ventricle and LV (biventricular stimulation). This mode of CR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2014