Introduction: The therapeutic monitoring of lithium, through concentration measurements, is important for individual dose adjustment, as a marker of treatment adherence and to prevent poisoning and side effects. Objectives: Validate and compare two methods – atomic emission and atomic absorption – for the determination of lithium in serum samples. Methodology: Parameters such as specificity, precision, accuracy, limit of detection (LOD) and linearity were considered. The atomic absorption spectrometer was used, operating in either emission or absorption mode. For the quantitative comparison of 30 serum samples from patients with mood disorder treated with lithium, the results were submitted to Student’s t-test, F-test and Pearson’s correlation. Results: The limit of quantification (LOQ) was established as 0.05 mEq/l of lithium, and calibration curves were constructed in the range of 0.05-2 mEq/l of lithium, using aqueous standards. Sample preparation time was reduced, what is important in medical laboratory. Conclusion: Both methods were considered satisfactory, precise and accurate and can be adopted for lithium quantification. In the comparison of quantitative results in lithium-treated patients through statistical tests, no significant differences were observed. Therefore the methods for lithium quantification by flame atomic absorption spectrometry (FAAS) and flame atomic emission spectrometry (FAES) may be considered similar.
منابع مشابه
Optimization, Calibration, and Validation of Atomic Absorption Spectrometry for Metal Analysis of Petroleum Products and Lubricants
2. Referenced Documents 2.1 ASTM Standards: D1318 Test Method for Sodium in Residual Fuel Oil (Flame Photometric Method) D3237 Test Method for Lead in Gasoline by Atomic Absorption Spectroscopy D3340 Test Method for Lithium and Sodium in Lubricating Greases by Flame Photometer D3605 Test Method for Trace Metals in Gas Turbine Fuels by Atomic Absorption and Flame Emission Spectroscopy D3831 Test...
متن کاملSaliva and serum lithium monitoring in hospitalized patients and possibility to replace serum to saliva.
The lithium ions concentration in human serum and saliva was determined using dry-slide technology Vitros 250 Analyser (Ortho Clinical Diagnostic) and atomic absorption spectrometry Perkin Elmer 403 (AAS). We analyzed lithium ions in 100 serum and saliva specimens of patients after oral administration of lithium carbonate (3 x 300 mg) Jadran, Galen Laboratory Rijeka. Saliva and blood were taken...
متن کاملComparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination
This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...
متن کاملDetermination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination
Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...
متن کاملValidation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil
BACKGROUND The aim of this paper was the validation of a new analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals (Ag, Cd, Co, Cr, Cu, Ni, Pb and Zn) in soil after microwave assisted digestion in aqua regia. Determinations were performed on the ContrAA 300 (Analyt...