Maximal expiratory flow at FRC (V'maxFRC): Methods of selection and differences in reported values.

نویسندگان

  • Anastassios C Koumbourlis
  • Xin C Chen
  • J Sunil Rao
  • Mark D Schluchter
  • Kirk Easley
  • Andrew A Colin
  • Peter Hiatt
  • Meyer Kattan
  • Kevin McCarthy
  • Robert B Mellins
  • Hannah Peavy
  • Arnold C G Platzker
  • Suzanne Steinbach
  • Andrew Ting
  • Michael D Weisner
  • Mary Ellen B Wohl
چکیده

We compared three methods of reporting maximal expiratory flow (V'maxFRC) measured in partial expiratory flow-volume curves (PEFVCs) at the point of functional residual capacity (FRC). PEFVCs were obtained with the rapid thoracoabdominal compression technique (RTC) on a total of 446 occasions in 281 HIV-negative, asymptomatic infants (4.8-28.1 months old). Three different expressions of V'maxFRC were recorded: 1) the highest measured flow (maxV'FRC), 2) the mean of the three highest flows (mean3V'FRC), and 3) the flow at FRC in a composite curve (compV'FRC) consisting of PEFVCs, obtained at different jacket pressures and superimposed at their distal limb. The numerical value of maxV'FRC was 7.4% (+/-5.6%) higher than the mean3V'FRC, and 11.9% (+/-17.7%) higher than the compV'FRC; the mean3V'FRC was 5% (+/-18.3%) higher than the compV'FRC. Bland-Altman analysis was used to evaluate the agreement between the three indices. The mean difference and 95% limits of agreement were: maxV'FRC -mean3V'FRC, 14 +/- 18 ml/sec; maxV'FRC - compV'(FRC), 23 +/- 58 ml/sec; and mean3V'(FRC) - compV'(FRC), 10 +/- 52 ml/sec. The differences between the slopes of the three indices (regressed against height) were statistically significant, although clinically unimportant. We conclude that despite their high correlation, the mean3V'FRC and maxV'FRC should not be used interchangeably, and that the composite analysis, although useful, does not improve the reproducibility of V'maxFRC, and thus it cannot be recommended for routine use in its current form.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Lung function at one month of age as a risk factor for infant respiratory symptoms in a high risk population.

BACKGROUND Abnormal premorbid lung function is a risk factor for subsequent wheezing in children with one or no atopic parent. This study was undertaken to establish whether early lung function in high risk infants (both parents atopic) was a risk factor for respiratory symptoms in infancy and to examine the influence of maternal asthma, smoking, and allergen exposure during pregnancy on any as...

متن کامل

Effects of Ramadan fasting on spirometric values and clinical symptoms in asthmatic patients

Introduction: Ramadan is the 9th  Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset.  The effect of Ramadan intermittent fasting on asthma control is controversial.  The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and M...

متن کامل

Early Lung Function Testing in Infants with Aortic Arch Anomalies Identifies Patients at Risk for Airway Obstruction

BACKGROUND Aortic arch anomalies (AAA) are rare cardio-vascular anomalies. Right-sided and double-sided aortic arch anomalies (RAAA, DAAA) are distinguished, both may cause airway obstructions. We studied the degree of airway obstruction in infants with AAA by neonatal lung function testing (LFT). PATIENTS AND METHODS 17 patients (10 RAAA and 7 DAAA) with prenatal diagnosis of AAA were invest...

متن کامل

COMPARISON OF THE BRONCHODIL ATORY EFFECTS OF INHALED SALBUTAMOLAND COMBIVEN T IN ASTHMATIC PATIENTS

A randomized, double-blind, crossover trial was designed to compare the acute effects of Combivent and salbutamol on spirometric parameters in patients with moderate to severe asthma. Nineteen patients with a mean baseline forced expiratory volume in 1 sec. (FEV]) less than 65% predicted, were randomized on two separate days to receive two puffs of salbutamol (200 µg) or two puffs of Combiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric pulmonology

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2004