Reproducibility of measurements of regional myocardial blood flow in a model of coronary artery disease: Comparison of H215O and 13NH3 PET techniques.

نویسندگان

  • Panithaya Chareonthaitawee
  • Stuart D Christenson
  • Jill L Anderson
  • Brad J Kemp
  • David O Hodge
  • Erik L Ritman
  • Raymond J Gibbons
چکیده

UNLABELLED PET absolute myocardial blood flow (MBF) with H(2)15O and 13NH3 are widely used in clinical and research settings. However, their reproducibility with a 16-myocardial segment model has not been examined in chronic coronary artery disease (CAD). We examined the short-term reproducibility of PET H(2)15O MBF and PET 13NH3 MBF in an animal model of chronic CAD. METHODS Twelve swine (mean weight +/- SD, 38 +/- 5 kg) underwent percutaneous placement of a copper stent in the mid circumflex coronary artery, resulting in an intense inflammatory fibrotic reaction with luminal stenosis at 4 wk. Each animal underwent repeated resting MBF measurements by PET H(2)15O and PET 13NH3. Attenuation-corrected images were analyzed using commercial software to yield absolute MBF (mL/min/g) in 16 myocardial segments. MBF was also normalized to the rate.pressure product (RPP). RESULTS By Bland-Altman reproducibility plots, the mean difference was 0.01 +/- 0.18 mL/min/g and 0.01 +/- 0.11 mL/min/g, with confidence limits of +/-0.36 and +/-0.22 mL/min/g for uncorrected regional PET H(2)15O MBF and for uncorrected regional PET 13NH3 MBF, respectively. The repeatability coefficient ranged from 0.09 to 0.43 mL/min/g for H(2)15O and from 0.09 to 0.18 mL/min/g for 13NH3 regional MBF. RPP correction did not improve reproducibility for either PET H(2)15O or PET 13NH3 MBF. The mean difference in PET H(2)15O MBF was 0.03 +/- 0.14 mL/min/g and 0.02 +/- 0.19 mL/min/g for infarcted and remote regions, respectively, and in PET 13NH3 MBF was 0.03 +/- 0.11 mL/min/g and 0.00 +/- 0.09 mL/min/g for infarcted and remote regions, respectively. CONCLUSION PET H(2)15O and PET 13NH3 resting MBF showed excellent reproducibility in a closed-chest animal model of chronic CAD. Resting PET 13NH3 MBF was more reproducible than resting PET H(2)15O MBF. A high level of reproducibility was maintained in areas of lower flow with infarction for both isotopes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lesions by Dipyridamole Echocardiography Comparison With Positron Emission Tomography and Quantitative Arteriography

Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve,...

متن کامل

Comparison With Positron Emission Tomography and Quantitative Arteriography

Background The aim of this study was to compare the results of dipyridamole-echocardiography test (DET: twodimensional echo monitoring during dipyridamole infusion up to 0.84 mg/kg over a period of 10 minutes) with both anatomic and physiological parameters of coronary artery disease severity, assessed by computer-assisted quantitative coronary arteriography, and regional coronary flow reserve,...

متن کامل

Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?

Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

Quantification of regional myocardial blood flow in vivo with H215O.

Using H215O (half-life = 2.1 min) we demonstrated that a modification of the tissue autoradiographic approach permitted quantitation of myocardial blood flow in open-chest dogs by direct assay of myocardial tissue and that noninvasive estimation with positron-emission tomography (PET) delineated relative myocardial blood flow in intact dogs. In open-chest anesthetized dogs, the single-pass extr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 7  شماره 

صفحات  -

تاریخ انتشار 2006