Development and positioning reliability of a TMS coil holder for headache research.
نویسندگان
چکیده
OBJECTIVE Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. METHODS A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimensional positional accuracy. Reliability of coil positioning was assessed by stimulating over the motor cortex of four neurologically normal subjects and recording finger muscle responses, both at a test phase and a retest phase several hours later. RESULTS In all four subjects, repositioning of the transcranial magnetic stimulation coil solely on the basis of coil holder coordinates was accurate to within 2 mm. CONCLUSIONS The coil holder demonstrated good test-retest reliability of coil positioning, and is thus a promising tool for transcranial magnetic stimulation-based headache research, particularly studies of prophylactic drug effect where several laboratory visits with identical coil positioning are necessary.
منابع مشابه
A new hardware-software coil positioning system for interleaved TMS/fMRI: A motor cortex stimulation study
Interleaved TMS/fMRI is a promising technique to study connectivity between brain areas. Functional connectivity can be assessed by targeting a cortical area-of-interest using TMS (Transcranial Magnetic Stimulation) and directly monitoring the effects on local and remote BOLD activity by means of fMRI. An important practical challenge is the accurate positioning of the coil inside the MRI scann...
متن کاملA novel coil array for combined TMS/fMRI experiments at 3 T.
PURPOSE To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. METHODS The state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitiv...
متن کاملComparative incidence rates of mild adverse effects to transcranial magnetic stimulation.
OBJECTIVES Past research has largely neglected to investigate mild adverse effects (MAEs) to transcranial magnetic stimulation (TMS), including headache and nausea. Here we explored the relationship between MAEs, participant characteristics (age and gender) and protocol parameters, including mode of application, coil geometry, stimulated brain region, TMS frequency, TMS intensity, and active vs...
متن کاملAdvancing Transcranial Magnetic Stimulation Methods for Complex Regional Pain Syndrome: An Open-Label Study of Paired Theta Burst and High-Frequency Stimulation.
INTRODUCTION Complex Regional Pain Syndrome (CRPS), a rare and severe chronic pain condition, often responds poorly to existing treatments. Previous studies demonstrated Transcranial Magnetic Stimulation (TMS) provided short-term pain relief for upper extremity CRPS. METHODS Building on previous methodologies, we employed a TMS protocol that may lead to significant pain relief for upper and l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Headache
دوره 45 1 شماره
صفحات -
تاریخ انتشار 2005