Data-driven persistent monitoring of Indoor Air Systems
نویسندگان
چکیده
Persistent monitoring of Indoor Air Quality (IAQ) within and around buildings and structures is critical to reduce risk of indoor health concerns. Specifically, IAQ issues in large integrated buildings may stem from inadequate ventilation and/or faults in the complex HVAC systems that together with control and communication systems can be considered as complex Cyber Physical Systems (CPSs). We propose a data-driven framework for monitoring distributed complex CPSs that reliably captures cyber and physical sub-system behaviors as well as their interaction characteristics. Using such learning methods, we aim to identify the anomalies and faults at an early stage such that necessary mitigation measures can be pursued in time. A fault in the HVAC system may be due to both physical and cyber anomalies affecting the operational goals of the building system. The proposed technique involves modeling of cyber and physical entities using probabilistic graphical models that capture individual characteristics of the sub-system and causal dependencies among different sub-systems. The proposed model can be trained using nominal historical data and then can be used to monitor the HVAC system and IAQ during regular operation. We validate our method with a case study on an integrated “zero-energy” (low energy/high performance) building, the Interlock House experimental test bed that is developed and maintained by the Center for Building Energy Research (CBER) at Iowa State.
منابع مشابه
Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations
The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...
متن کاملIndoor air quality monitoring in urban areas using Smart Sensing Technology
Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...
متن کاملThe Monitoring of Fungal Contamination in Indoor Air of Two Hospitals in Shiraz
Introduction: Hospitals, as one of the important elements in the health system, play an important role in patient’s health. Fungi are one of the effective parameters on indoor air quality. This study aimed to compare of fungal contamination of two hospitals in Shiraz City. Materials and Methods: Sampling was conducted based on NIOSH 0800 standard (1.5 meters above the ground level with one sta...
متن کاملبررسی غلظت ذرات معلق در هوای داخل کلاس و هوای بیرون و عوامل تأثیرگذار آن در مدارس راهنمایی و دبیرستان شهر یزد
Abstract Introduction: Airborne pollution in such public environments as schools has adverse health effects on pupils and teachers who spend a noticeable amount of time in the school. Therefore, this study aimed to measure the suspended particles concentration of indoor and outdoor air of Yazd schools as well as to determine the influencing parameters on the pollution intensity. Metho...
متن کاملMonitoring Indoor Air Quality to Improve Occupational Health
Indoor environments are characterized by several pollutant sources. As people typically spend more than 90% of their time in indoor environments. Thus, indoor air quality (iAQ) is recognized as an important factor to be controlled for the occupants’ health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This wor...
متن کامل