Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability
نویسندگان
چکیده
Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France). Three consecutive measurements were obtained. The within-subject standard deviation (Sw ), intrasubject precision (1.96 × Sw ), and intraclass correlation coefficient (ICC) were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm) was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS) were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689). Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes.
منابع مشابه
Repeatability of aberrometric measurements with a new instrument for vision analysis based on adaptive optics.
PURPOSE To evaluate intersession and intrasession repeatability of aberration data obtained with a new visual simulator based on adaptive optics, which includes a Hartmann-Shack aberrometer (Adaptive Optics Vision Analyzer; Voptica S.L., Murcia, Spain). METHODS Thirty-one healthy right eyes were included in the study. To evaluate intrasession repeatability, three consecutive measurements with...
متن کاملRepeatability of aberrometric measurements in normal and keratoconus eyes using a new Scheimpflug-Placido topographer.
PURPOSE To evaluate the repeatability of the anterior and posterior corneal wavefront aberrations using the Sirius Scheimpflug-Placido topographer in normal eyes and keratoconus eyes. SETTING Bozok University Faculty of Medicine, Yozgat, Turkey. DESIGN Evaluation of diagnostic test. METHODS In eyes of healthy subjects and eyes of keratoconus patients, 3 repeated measurements were obtained...
متن کاملRepeatability of manual subfoveal choroidal thickness measurements in healthy subjects using the technique of enhanced depth imaging optical coherence tomography.
PURPOSE The aim of this study was to investigate the repeatability of manual measurements of choroidal thickness in healthy subjects imaged on spectral domain optical coherence tomography (OCT) using the enhanced depth imaging (EDI) technique. METHODS Fifty consecutive, healthy, young, adult volunteers with no known eye disease were enrolled prospectively. Two good-quality horizontal and vert...
متن کاملOPD scan III accuracy: Topographic and aberrometric indices after accelerated corneal cross-linking
Purpose To determine topographic and aberrometric changes after accelerated cross-linking (ACXL; 18 mW/cm2 for 5 min) as measured with OPD Scan III (Nidek Inc., Tokyo, Japan) and their repeatability in patients with mild and moderate keratoconus (KCN). Methods In this prospective study, 25 eyes with mild KCN [Ksteep = 47.24 ± 3.11 diopter (D)] and 20 moderate cases (Ksteep = 52.86 ± 4.39 D) w...
متن کاملReliability of noncontact pachymetry after laser in situ keratomileusis.
PURPOSE To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements obtained by combined scanning-slit/Placido-disc topography (Orbscan II; Bausch & Lomb, Rochester, NY) after laser in situ keratomileusis (LASIK) and to compare the results with another noncontact method, specular microscopy (SP-2000P; Topcon, Tokyo, Japan). METHODS To analyze intrasession r...