Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula.

نویسندگان

  • Jeffrey E Hull
  • Boris V Balakin
  • Brad M Kellerman
  • David K Wrolstad
چکیده

OBJECTIVE The goal of this research was to compare side-to-side (STS) and end-to-side (ETS) anastomoses in a computer model of the arteriovenous fistula with computational fluid dynamic analysis. METHODS A matrix of 17 computer arteriovenous fistula models (SolidWorks, Dassault Systèmes, France) of artery-vein pairs (3-mm-diameter artery + 3-mm-diameter vein and 4-mm-diameter artery +6-mm-diameter vein elliptical anastomoses) in STS, 45° ETS, and 90° ETS configurations with cross-sectional areas (CSAs) of 3.5 to 18.8 mm(2) were evaluated with computational fluid dynamic software (STAR-CCM+; CD-adapco, Melville, NY) in simulations at defined flow rates from 600 to 1200 mL/min and mean arterial pressures of 50 to 140 mm Hg. Models and configurations were evaluated for pressure drop across the anastomosis, arterial inflow, venous outflow, arterial outflow, velocity vector, and wall shear stress (WSS) profile. RESULTS Pressure drop across the anastomosis was inversely proportional to anastomotic CSA and to venous outflow and was proportional to arterial inflow. Pressure drop was greater in 3 + 3 models than in 4 + 6 STS models; 90° ETS configurations had the lowest pressure drops and were nearly identical, whereas 45° ETS configurations had the highest pressure drops. Venous outflow in the 4 + 6 model in STS configurations, evaluated at 100 mm Hg arterial inflow pressure, was 390, 592, 610, and 886 mL/min in anastomotic CSAs of 3.5, 5.3, 7.1, and 18.8 mm(2), respectively, and was similar in 90° ETS (609 and 908 mL/min) and lower in 45° ETS (534 and 562 mL/min) configurations at CSAs of 5.3 and 18.8 mm(2). The mean increase in venous outflow was 69 mL/min (range, -59 to 134) between 3 + 3 and 4 + 6 models at 100 mm Hg arterial inflow. The most uniform WSS profile occurs in STS anastomoses followed by 45° ETS and then 90° ETS anastomoses. CONCLUSIONS The STS and 90° ETS anastomoses have high venous outflow and a tendency toward reversed arterial outflow. The 45° ETS anastomosis has reduced venous outflow but resists reversed arterial outflow. The STS anastomosis has more uniform WSS characteristics compared with the 45° and 90° ETS anastomoses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Analysis of Radiocephalic Fistula Using Side-to-side Anastomosis with Distal Cephalic Vein Ligation

BACKGROUND The surgically created arteriovenous fistula has recently been recommended as the best available angioaccess for hemodialysis. Therefore, in this study, we carried out a clinical analysis on surgical procedures in the ligation and division of a distal vein to achieve similar effects as those of vein end-to-arterial side after side-to-side anastomosis. METHODS We retrospectively rev...

متن کامل

Numerical investigations of the unsteady blood flow in the end-to-side arteriovenous fistula for hemodialysis.

PURPOSE The aim of this study was to investigate the blood flow in the end-to-side arteriovenous (a-v) fistula, taking into account its pulsating nature and the patient-specific geometry of blood vessels. Computational Fluid Dynamics (CFD) methods were used for this analysis. METHODS DICOM images of the fistula, obtained from the angio-computed tomography, were a source of the data applied to...

متن کامل

Arterio venous fistula experience at a tertiary care hospital in Pakistan

OBJECTIVE To evaluate the two year patency rate of functioning arteriovenous fistula. METHODOLOGY This prospective case series study was conducted at Department of Urology, Jinnah Postgraduate Medical Centre, Karachi, from 1(st) January 2009 to 31(st) December, 2010. Patients were chosen for CBRC arteriovenous fistula at wrist and patients undergoing other types of vascular access or secondar...

متن کامل

The advantages of end-to-side arteriovenous anastomosis over the other two types of arteriovenous anastomosis in dialysis patients.

The functional duration of vascular access in dialysis patients depends on the emergence of threatening complications. Discussions are constantly being held in an attempt to discover their causality and decrease their emergence. In 260 patients undergoing haemodialysis, we have studied the potential existence of a cause-and-effect relation between the emergence of complications in the vascular ...

متن کامل

Usefulness of dynamic renal scintigraphy in a patient with renal arteriovenous fistula treated by transcatheter embolization.

Tc-99m-DTPA renal scintigraphy was performed before and after transcatheter coil embolization in a patient with renal arteriovenous fistula (AVF). Before embolization, scintigraphy showed a characteristic accumulation pattern compatible with the hemodynamics of an aneurysmal type of AVF in the vascular phase. After embolization, the effects of treatment, such as a change in the split renal func...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2013