Functional and anatomical diagnosis of coronary artery stenoses.

نویسندگان

  • Abhijit Sinha Roy
  • Martin R Back
  • Saeb F Khoury
  • Eric W Schneeberger
  • Lloyd H Back
  • Vijaya V Velury
  • Ronald W Millard
  • Rupak K Banerjee
چکیده

BACKGROUND Functional/physiological evaluation of coronary artery stenoses may be more important than anatomical measurements of severity. Optimization of thresholds for stenosis intervention and treatment endpoints depend on coupling functional hemodynamic and anatomical data. We sought to develop a single prognostic parameter correlating stenosis-specific anatomy, pressure gradient, and velocities that could be measured during catheterization. MATERIALS AND METHODS In vivo Experiments were performed in six swine (41 +/- 3 kg). The lumen area of the left anterior descending coronary artery was measured with intravascular ultrasound. An angioplasty balloon was inflated to create the desired intraluminal area obstructions. Fractional flow reserve (FFR), coronary flow reserve (CFR), and hyperemic-stenosis-resistance index were measured distal to the balloon at peak hyperemia with 10 mg intracoronary papaverine. A functional index:pressure drop coefficient (CDP) and a combined functional and anatomical index:lesion flow coefficient (LFC) were calculated from measured hyperemic pressure gradient, velocity, and percentage area stenosis. P < 0.05 was considered statistically significant. RESULTS The CDP and LFC correlated linearly and significantly with FFR and CFR. The CDP (R(2) = 0.72, P < 0.0001) correlated better than LFC (R(2) = 0.19, P < 0.003) with hyperemic-stenosis-resistance index. When LFC was correlated simultaneously with FFR and CFR, R(2) improved to 0.82 (P < 0.0001). Inclusion of percentage area stenoses concurrently with FFR and CFR marginally improved the correlation with LFC. CONCLUSIONS A dimensionless parameter combining measured pressure gradient, velocity, and area reduction data can optimally define the severity of coronary stenoses based on our preliminary results and could prove useful clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Anatomical and Functional Modalities in Detection of Silent Myocardial Ischemia in Asymptomatic Diabetic Patients- A Review Article

Cardiovascular disease (CAD) screening in asymptomatic patients with diabetes mellitus is controversial. An exercise stress test is a safe and effective initial testing for Ischemic Heart Disease (IHD) screening. Treadmill stress test is not the best screening method for a particular patient who is not able to exercise, abnormal electrocardiogram (ECG) or positive exercise treadmill test (ETT) ...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

Subacute bilateral coronary ostial stenoses following cardiac catheterization and PTCA.

Accelerated coronary ostial stenosis is an infrequent late complication of coronary artery catheter instrumentation during aortic valve surgery, PTCA, or coronary angiography. We report the first case of bilateral coronary artery ostial stenoses developing after cardiac catheterization and right coronary artery PTCA. In patients with worsening angina following cardiac catheterization or PTCA, a...

متن کامل

The effect of turbulence model on predicting the development and progression of coronary artery atherosclerosis

A severe case of stenosis in coronary arteries results in turbulence in the blood flow which may lead to the formation or progression of atherosclerosis. This study investigated the turbulent blood flow in a coronary artery with rigid walls, as well as 80% single and double stenoses on blood flow. A finite element-based software package, ADINA 8.8, was employed to model the blood flow. The hemo...

متن کامل

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

OBJECTIVE To evaluate the diagnostic accuracy of dual-source computed tomography (DSCT) in the diagnosis of coronary artery stenoses by comparing with conventional coronary angiography (CCA). METHODOLOGY CCA and DSCT were performed in 64 patients with suspected coronary artery disease (CAD) respectively (46 male, 18 female, age from 48 to 82 years old, mean 68.18 years). Various post-processi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of surgical research

دوره 150 1  شماره 

صفحات  -

تاریخ انتشار 2008