Hemodynamic segmentation of MR perfusion images in patients with unilateral carotid stenosis using independent component analysis.
نویسندگان
چکیده
PURPOSE To assess spatiotemporal patterns of local perfusion in MR brain perfusion images for patients with unilateral carotid stenosis. MATERIALS AND METHODS MR perfusion images acquired from 12 patients with unilateral carotid stenosis were retrospectively segmented using independent component analysis. Regions of interest selected from the segmentation results were used to measure the time to peak (TTP), time to maximum of the residue curve (Tmax), and mean transit time (MTT) for arteries and brain parenchyma on normal and stenotic sides. RESULTS The tissue types that can be identified in segmentation results include normal artery, artery with proximal stenosis, normal brain parenchyma, delayed-perfusion brain parenchyma, vein and sinus, choroid plexus, cerebrospinal fluid, and leukoaraiosis. Concentration-time curves measured on normal and stenotic artery regions can be modeled as two arterial input functions. Unilateral carotid stenosis associated with either middle cerebral artery stenosis or poor collateral circulation at the circle of Willis resulted in increased differences of brain parenchyma TTP, Tmax, and MTT between normal and stenotic sides. CONCLUSION Independent component analysis on perfusion images of patients with unilateral carotid stenosis provides useful spatiotemporal information regarding blood supply to arteries and local perfusion of brain parenchyma.
منابع مشابه
Hemodynamic modifications in patients with symptomatic unilateral stenosis of the internal carotid artery: evaluation with MR imaging perfusion sequences.
BACKGROUND AND PURPOSE Risk of developing ischemia is higher in patients with reduced cerebrovascular reactivity than in those with preserved cerebrovascular reactivity. Therefore, we assessed cerebral hemodynamic modifications in patients with unilateral stenosis of the internal carotid artery by using perfusion-weighted MR imaging to determine if these modifications underlie or anticipate isc...
متن کاملPreoperative Cerebral Oxygen Extraction Fraction Imaging Generated from 7T MR Quantitative Susceptibility Mapping Predicts Development of Cerebral Hyperperfusion following Carotid Endarterectomy.
BACKGROUND AND PURPOSE Preoperative hemodynamic impairment in the affected cerebral hemisphere is associated with the development of cerebral hyperperfusion following carotid endarterectomy. Cerebral oxygen extraction fraction images generated from 7T MR quantitative susceptibility mapping correlate with oxygen extraction fraction images on positron-emission tomography. The present study aimed ...
متن کاملHemodynamic Segmentation of Brain Perfusion Images with Delay and Dispersion Effects Using an Expectation-Maximization Algorithm
Automatic identification of various perfusion compartments from dynamic susceptibility contrast magnetic resonance brain images can assist in clinical diagnosis and treatment of cerebrovascular diseases. The principle of segmentation methods was based on the clustering of bolus transit-time profiles to discern areas of different tissues. However, the cerebrovascular diseases may result in a del...
متن کاملDetection of cerebral hypoperfusion in patients with unilateral Severe Internal Carotid Artery Stenosis by Arterial Spin labeling MR Imaging: Comparison with Dynamic Contrast Perfusion MR Image
X. Lou, Y-Q. Cai, L. Ma, W. Sun, X-M. Li Radiology, PLA General Hospital, Beijing, Beijing, China, People's Republic of, GE Healthcare, China, Beijing, Beijing, China, People's Republic of, Neurology, PLA General Hospital, Beijing, Beijing, China, People's Republic of Introduction Patients with symptomatic severe stenosis of the internal carotid artery (ICA) [1] are at risk for future ischemic ...
متن کاملCerebral hemodynamics in relation to patterns of collateral flow.
BACKGROUND AND PURPOSE We sought to investigate the relation between collateral flow via different pathways and hemodynamic parameters measured by dynamic susceptibility contrast-enhanced MRI in patients with severe carotid artery disease. METHODS Dynamic susceptibility contrast-enhanced MRI was performed in 66 patients and 33 control subjects. Patients had severe stenosis (>70%, n=12), unila...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2008