The BUDDY (Bedside Ultrasound to Detect Dehydration in Youth) study

نویسندگان

  • Joshua Jauregui
  • Daniel Nelson
  • Esther Choo
  • Branden Stearns
  • Adam C Levine
  • Otto Liebmann
  • Sachita P Shah
چکیده

BACKGROUND Prior research suggests that the ratio of the ultrasound-measured diameter of the inferior vena cava to the aorta correlates with the level of dehydration in children. This study was designed to externally validate this and to access the accuracy of the ultrasound measured inspiratory IVC collapse and physician gestalt to predict significant dehydration in children in the emergency department. METHODS We prospectively enrolled a non-consecutive cohort of children ≤18 years old. Patient weight, ultrasound measurements of the IVC and Ao, and physician gestalt were recorded. The percent weight change from presentation to discharge was used to calculate the degree of dehydration. A weight change of ≥5% was considered clinically significant dehydration. Receiver operating characteristic (ROC) curves were constructed for each of the ultrasound measurements and physician gestalt. Sensitivity (SN) and specificity (SP) were calculated based on previously established cutoff points of the IVC/Ao ratio (0.8), the IVC collapsibility index of 50%, and a new cut off point of IVC collapsibility index of 80% or greater. Intra-class correlation coefficients were calculated to assess the degree of inter-rater reliability between ultrasound observers. RESULTS Of 113 patients, 10.6% had significant dehydration. The IVC/Ao ratio had an area under the ROC curve (AUC) of 0.72 (95% CI 0.53 to 0.91) and, with a cutoff of 0.8, produced a SN of 67% and a SP of 71% for the diagnosis of significant dehydration. The IVC collapsibility index of 50% had an AUC of 0.58 (95% CI 0.44 to 0.72) and, with a cutoff of 80% collapsibility, produced a SN of 83% and a SP of 42%. The intra-class correlation coefficient was 0.83 for the IVC/Ao ratio and 0.70 for the IVC collapsibility. Physician gestalt had an AUC of 0.61 (95% CI 0.44 to 0.78) and, with a cutoff point of 5, produced a SN of 42% and a SP of 65%. CONCLUSIONS The ultrasound-measured IVC/Ao ratio is a modest predictor of significant dehydration in children. The inspiratory IVC collapse and physician gestalt were poor predictors of the actual level of dehydration in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Ultrasound-Assisted Osmotic Dehydration Pretreatment on the Convective Drying of Apple Slices (var.Golab)

Drying is one of the widely used methods of food preservation and it is a sensitive food processing operation due to undesirable changes in the quality of dried product. In this study the effect of osmotic dyhedration and ultrasound pretreatment prior to convective drying on quality properties of apple slices was investigated. Apple slices were pretreated by osmotic dehydration in two concentra...

متن کامل

Modeling and Optimization of Ultrasound-Assisted Osmotic Dehydration with Finished Freeze Drying on Black Cherries – The Effect on Antioxidant Activities

ABSTRACT: In this study, response surface methodology was used to optimize ultrasound osmotic pretreatment with finished freeze drying of black cherries. Freeze drying is a separation process based on the  sublimation phenomenon. This process has the following advantages as compared to the conventional drying process, maintenance of the structure, moisture removal at low temperature (reduced tr...

متن کامل

Extremity Fracture Diagnosis Using Bedside Ultrasound in Pediatric Trauma Patients Referring to Emergency Department; A Diagnostic Study

Background This study performed to assess the efficacy of ultrasound in screening upper and lower extremities fractures in comparison with standard X-ray in pediatric trauma patients. Materials and Methods This was a prospective diagnostic study conducted at the emergency department of Imam Khomeini Complex Hospital, Tehran, Iran. All patients with the age under 18-year-old admitted with limb t...

متن کامل

Comparing the diagnostic accuracy of bedside ultrasound with wound exploration in diagnosis of nerve and tendon injuries in upper extremities: a brief report

Background: Trauma is one of the most common causes of death in all ages. Considering the prevalence of trauma in the general population, and its costs and complications, it is important to use aiding tools to accelerate the diagnosis in order to act in time. The aim of this study was to evaluate the efficacy of ultrasound in diagnosing nerve and tendon injuries in the upper extremities. Metho...

متن کامل

Bedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CTComparative Diagnostic Study

Background: Some of the Mason type I fractures cannot be detected on early radiographic images. These occultfractures are considered as a diagnostic challenge for physicians. Our aim was to determine the value of bedsideultrasonography for the detection of Mason I radial head fractures that are non-visible in early X-ray’s.Methods: A prospective blind single-center diagnostic study was conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014