Instant velocity and consistency of emitted cloud change by the different levels of canister filling with Metered Dose Inhalers (MDIs), but not with Soft Mist Inhalers (SMIs): a bench study
نویسندگان
چکیده
BACKGROUND Inhalation is the preferred route for respiratory drug delivery, but several factors contribute to the variability of the respirable dose fraction. Instant velocity and the dynamic characteristics of the droplet cloud represent crucial factors. Aim was to measure and compare the instant velocity and the consistency of emitted cloud from five different MDIs (A - Salbutamol sulphate 100mcg, GSK; B - Salbutamol sulphate 100mcg, Valeas; C - Salmeterol xinafoate/Fluticasone propionate 25/125mcg, GSK; D - Formoterol fumarate/Bechlomethasone propionate 6/100mcg, Chiesi; E - Formoterol fumarate/Fluticasone dipropionate 5/125mcg, Mundipharma) and one SMI (Tiotropium bromide 5mcg, Boehringer Ingelheim), at different distance from the nozzle and canister filling. METHODS Measurements were made at 90, 50, and 10% of canister filling, and at 5, 10, and 20 cm from the nozzle, for a total of 972 puffs. A high speed video photography protocol was adopted and high speed cameras (1.200 frames/sec.) were used. Data were acquired by means of specialized softwares. Temperature, humidity, and vibrations occurrence were strictly controlled during measurements. Statistics: Anova and p < 0.05 were accepted as the minimum significance level. RESULTS MDIs generated different Instant velocities: MDI B generated the highest, while MDI A the lowest. As expected, velocity decreased in proportion to the distance from the nozzle. Except with MDI C, instant velocity decreased significantly over the first 50% of canister emptying, but dropped by >33% at 90% of emptying with all other MDIs (p < 0-037; p < 0.001; p < 0.005, and p < 0.001, respectively). Instant velocity was extremely lower (p < 0.001) and constant for all levels of canister filling (p = ns) with SMI. All MDIs had a very fast jet phase, ranging 0.01-0.03 s at 10 cm, and 0.03-0.05 s at 20 cm from the nozzle, without any significant difference from each other (p = ns). MDIs generated a cloud similarly tight (p = ns) at 10 and 20 cm from the nozzle, while it was extremely wider and constant with the SMI (p = 0-001). Also the cloud turbulence was minimized during the SMI emission. DISCUSSION AND CONCLUSIONS MDIs are characterized by a substantial variability in both their instant velocity and consistency of the emitted cloud at different levels of canister filling. SMI generates a much slower soft mist cloud which is constantly homogeneous and independent of canister emptying. These peculiarities assessed at bench are suggesting a higher dose consistency and a much more effective therapeutic performance also in real life.
منابع مشابه
Usage Pattern, Satisfaction, Causes of Concern and Related Factors of Metered Dose Inhalers in Children with Asthma, the Parents Perspective
Introduction Metered Dose Inhalers (MDIs) are the most common drugs for the control of asthma. This study was conducted to evaluate usage patterns, satisfaction with and concerns about MDIs for children with asthma and the related factors from the viewpoints’ of their parents. Materials and methods This cross-sectional study was conducted on children with asthma who referred to asthma and a...
متن کاملAlbuterol metered dose inhaler performance under hyperbaric pressures.
The weight change per actuation and aerosol particle size and number delivered by albuterol metered dose inhalers (MDIs) were measured in a multiplace hyperbaric chamber at pressures ranging from one atmosphere absolute (1 ATA, 0 feet of seawater, fsw, 101 kPa) to three ATA (66 fsw, 304 kPa). Weight change per actuation by CFC (chlorofluorocarbon) and long canister HFA (hydrofluoroalkane) power...
متن کاملPatterns of use of dry powder inhalers versus pressurized metered-dose inhalers devices in adult patients with chronic obstructive pulmonary disease or asthma: An observational comparative study
Numerous patients with chronic obstructive pulmonary disease (COPD) and asthma do not use inhaler devices properly, which can contribute to poor disease control. The objective of this study is to assess the technical and safety use of dry powder inhalers (DPIs) versus pressurized metered-dose inhalers (MDIs) in adult patients with COPD or asthma in Lebanon. A concurrent, prospective comparative...
متن کاملOronasal and Tracheostomy Delivery of Soft Mist and Pressurized Metered-Dose Inhalers With Valved Holding Chamber.
BACKGROUND Some pediatric tracheostomized patients who receive inhaled drugs undergo decannulation, and it is unknown whether the dose has to be adjusted. Pressurized metered-dose inhalers (pMDIs) and soft mist inhalers (SMIs) used with valved holding chambers (VHCs) made of non-electrostatic material are available. We hypothesized that using an SMI and changing the delivery route from tracheos...
متن کاملBronchodilator delivery with metered-dose inhalers in mechanically-ventilated patients.
Metered-dose inhalers (MDIs) provide several advantages over nebulizers, including ease of administration, decreased cost, reliability of dosing, and freedom from contamination. However, this method of aerosol delivery has been considered ineffective in mechanically-ventilated patients because most of the aerosol deposits in the endotracheal tube and ventilator circuit. A smaller amount of aero...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017