Intra-observer, inter-observer and inter-scanner variations in brain MRI volume measurements in multiple sclerosis.
نویسندگان
چکیده
INTRODUCTION Measurement of brain volume on magnetic resonance imaging (MRI) scans is regarded as an objective marker of multiple sclerosis (MS) severity with the potential to monitor treatment efficacy accurately. This study was performed to assess the variability of brain MRI volume measurements. PATIENTS AND METHODS We studied nine patients with relapsing-remitting MS, who were imaged on two occasions (separated by an interval of 24 h) using two different MR scanners and fast fluid-attenuated inversion recovery (fast-FLAIR) sequences. The whole brain volume computed from each image was measured three times by three observers using a seed-growing technique based on signal intensity thresholding. Intra-observer, inter-observer and inter-scanner variabilities were expressed as coefficients of variations (COVs). The inter-scanner variability included not only the intra-observer variation but also the repositioning variability and the variation in observed brain volume caused by different scanner hardware and sequence implementations. RESULTS There was no statistically significant difference in patients' brain volume values between observers (P=0.82) or between scanners (P=0.30). The mean intra-observer COV was 1.2% (s.e.=0.4%), the mean inter-observer COV was 1.8% (s.e.=0.8%) and the mean inter-scanner COV was 2.4% (s.e.=1.2%). The intra-observer variance was not statistically different from those found between observers (P=0.83) or scanners (P=0.44). CONCLUSION The intra-observer variability in brain volume measurements found in this study was within the range of intra-observer variability found in previous studies. This study shows that the use of different observers and MR scanners has only a small influence on the measured brain volume and does not affect the reproducibility of this measurement greatly.
منابع مشابه
Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملA New Index to Measure Intra-observer Variation in Delineating GTV Primary in Head and Neck Cancer
A critical step in radiotherapy treatment planning process is to accurately locate the tumor and determine its extent. Variability in gross tumor volume (GTV) delineation is a major source of systematic error in conformal radiotherapy. CT scan is the principle source of imaging data used for defining GTV for planning conformal therapy. CT is widely available less costly and compatible with radi...
متن کاملReproducibility of 3D free-breathing magnetic resonance coronary vessel wall imaging.
AIMS Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS MR...
متن کاملTracking the scapula using the scapula locator with and without feedback from pressure-sensors: A comparative study.
BACKGROUND The scapula locator method has associated intra-observer and inter-observer errors caused by the dependency on the observer to locate the scapular landmarks. The potential effect of the pressures applied by the observer on the measured scapular kinematics when this method is used has also been overlooked so far. The aim of this study was to investigate the effect of using feedback on...
متن کاملInter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures
Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures. Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Multiple sclerosis
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2001