Impedance spectroscopy using maximum length sequences: application to single cell analysis.

نویسندگان

  • Shady Gawad
  • Tao Sun
  • Nicolas G Green
  • Hywel Morgan
چکیده

A maximum length sequence (MLS) is used to perform broadband impedance spectroscopy on a dielectric sample. The method has a number of advantages over other pulse-based or frequency sweep techniques. It requires the application of a very short sequence of voltage steps in the microsecond range and therefore allows the measurement of time-dependent impedance of a sample with high temporal resolution over a large bandwidth. The technique is demonstrated using a time-invariant passive RC network. The impedance of single biological cell flowing in a microfluidic channel is also measured, showing that MLS is an ideal method for high speed impedance analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadband single cell impedance spectroscopy using maximum length sequences

Measurements of the dielectric (or impedance) properties of cells can be used as a general characterization and diagnostic tool. In this paper, we describe a novel impedance spectroscopy technique for the analysis of single biological cells in suspension. The technique uses maximum length sequences (MLS) for periodic excitation signal in a microfluidic impedance cytometer. The method allows mul...

متن کامل

High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences.

A novel impedance spectroscopy technique has been developed for high speed single biological particle analysis. A microfluidic cytometer is used to measure the impedance of single micrometre sized latex particles at high speed across a range of frequencies. The setup uses a technique based on maximum length sequence (MLS) analysis, where the time-dependent response of the system is measured in ...

متن کامل

Study the Effect of Silicon Nanowire Length on Characteristics of Silicon Nanowire Based Solar Cells by Using Impedance Spectroscopy

Silicon nanowire (SiNW) arrays were produced by electroless method on polycrystalline Si substrate, in HF/ AgNO3 solution. Although the monocrystalline silicon wafer is commonly utilized as a perfect substrate, polycrystalline silicon as a low cost substrate was used in this work for photovoltaic applications. In order to study the influence of etching time (which affects the SiNWs length) on d...

متن کامل

Review Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening

Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...

متن کامل

Electrochemical Impedance Spectroscopy for Investigation of Different Losses in 4-cells Short Stack with Integrated Humidifier and Water Separator

Electrochemical impedance spectroscopy (EIS) is a suitable and powerful diagnostic testing method for fuel cells (FCs) since it is non-destructive and provides useful information about FC performance and its components. In this study, for the first time, a 500W cascade type 4 cells stack with integrated humidifier, water separator and internal manifolds was designed, fabricated and tested. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 5  شماره 

صفحات  -

تاریخ انتشار 2007