Breathing Maneuvers as a Vasoactive Stimulus for Detecting Inducible Myocardial Ischemia – An Experimental Cardiovascular Magnetic Resonance Study
نویسندگان
چکیده
BACKGROUND Breathing maneuvers can elicit a similar vascular response as vasodilatory agents like adenosine; yet, their potential diagnostic utility in the presence of coronary artery stenosis is unknown. The objective of the study is to investigate if breathing maneuvers can non-invasively detect inducible ischemia in an experimental animal model when the myocardium is imaged with oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). METHODS AND FINDINGS In 11 anesthetised swine with experimentally induced significant stenosis (fractional flow reserve <0.75) of the left anterior descending coronary artery (LAD) and 9 control animals, OS-CMR at 3T was performed during two different breathing maneuvers, a long breath-hold; and a combined maneuver of 60s of hyperventilation followed by a long breath-hold. The resulting change of myocardial oxygenation was compared to the invasive measurements of coronary blood flow, blood gases, and oxygen extraction. In control animals, all breathing maneuvers could significantly alter coronary blood flow as hyperventilation decreased coronary blood flow by 34±23%. A long breath-hold alone led to an increase of 97±88%, while the increase was 346±327% (p<0.001), when the long breath-hold was performed after hyperventilation. In stenosis animals, the coronary blood flow response was attenuated after both hyperventilation and the following breath-hold. This was matched by the observed oxygenation response as breath-holds following hyperventilation consistently yielded a significant difference in the signal of the MRI images between the perfusion territory of the stenosis LAD and remote myocardium. There was no difference between the coronary territories during the other breathing maneuvers or in the control group at any point. CONCLUSION In an experimental animal model, the response to a combined breathing maneuver of hyperventilation with subsequent breath-holding is blunted in myocardium subject to significant coronary artery stenosis. This maneuver may allow for detecting severe coronary artery stenosis and have a significant clinical potential as a non-pharmacological method for diagnostic testing in patients with suspected coronary artery disease.
منابع مشابه
Mechanism of decreased sensitivity of dobutamine associated left ventricular wall motion analyses for appreciating inducible ischemia in older adults
BACKGROUND Dobutamine associated left ventricular (LV) wall motion analyses exhibit reduced sensitivity for detecting inducible ischemia in individuals with increased LV wall thickness. This study was performed to better understand the mechanism of this reduced sensitivity in the elderly who often manifest increased LV wall thickness and risk factors for coronary artery disease. METHODS Durin...
متن کاملIschemic burden by 3-dimensional myocardial perfusion cardiovascular magnetic resonance: comparison with myocardial perfusion scintigraphy.
BACKGROUND The extent and severity of ischemia on myocardial perfusion scintigraphy (MPS) is commonly used to risk-stratify patients with coronary artery disease. Estimation of ischemic burden by cardiovascular magnetic resonance (CMR) with conventional 2-dimensional myocardial perfusion methods is limited by incomplete cardiac coverage. More recently developed 3-dimensional (3D) myocardial per...
متن کاملStress Perfusion Cardiac Magnetic Resonance Imaging Effectively Risk Stratifies Diabetic Patients With Suspected Myocardial Ischemia.
BACKGROUND Diabetics remain at high risk of cardiovascular disease and mortality despite advancements in medical therapy. Noninvasive cardiac risk profiling is often more difficult in diabetics owing to the prevalence of silent ischemia with unrecognized myocardial infarction, reduced exercise capacity, nondiagnostic electrocardiographic changes, and balanced ischemia from diffuse epicardial co...
متن کاملDetecting left ventricular myocardial ischemia during intravenous dobutamine with cardiovascular magnetic resonance imaging (MRI).
Advances in computer software, scanner hardware, and hemodynamic monitoring equipment have permitted the development of cardiovascular stress testing protocols for use during intravenous Dobutamine infusions within magnetic resonance imaging (MRI) scanners. Recent studies have documented that the safety profile and clinical utility of Dobutamine/Atropine cardiac stress testing during MRI compar...
متن کاملMagnetic resonance imaging of ischemic heart disease.
Cardiac MRI has long been recognized as an accurate and reliable means of evaluating cardiac anatomy and ventricular function. Considerable progress has been made in the field of cardiac MRI, and cardiac MRI can provide accurate evaluation of myocardial ischemia and infarction (MI). Late gadolinium (Gd)-enhanced MRI can clearly delineate subendocardial infarction, and the assessment of transmur...
متن کامل