[Mid-term results of cementless ultima cups in primary total hip replacement].
نویسندگان
چکیده
PURPOSE OF THE STUDY To present the results of primary total hip arthroplasty (THA) with use of the hemispheric threaded Ultima cup at 8.5-year follow-up. MATERIAL Between 1996 and 1999, a total of 40 Ultima acetabular components were used in 33 patients (15 men and 18 women). The average age at the time of surgery was 61.2 years (range, 45 to 71). By the end of 2006, 36 cups were assessed. Indications for the primary THA procedure included primary arthritis in 32 hips, post-traumatic arthritis in three, post-dysplastic arthritis in two, femoral neck fracture in two and rheumatoid arthritis in one. METHODS The average follow-up was 8.5 years (range, 7 to 10). The indication criteria for primary implantation were evaluated, i.e., body mass index, patients' activity and their age. THA outcome was evaluated on the basis of clinical rating (Harris hip score) and pain assessment and on radiographic findings on which the acetabulum before and cup position after THA were compared, and potential changes in cup position, acetabular cup loosening or para-articular ossifications were observed. RESULTS Good outcomes were found in 88.9 % of the hips. In most, cup position was satisfactory. One acetabular component was implanted in a varus position (34 degrees ). An intraoperative complication included fracture of the greater trochanter, which was left untreated for spontaneous healing. The early-postoperative complications were one dislocation, two wounds with serous secretion not requiring revision surgery, and one large haematoma. Stem fracture as a late complication was recorded in two THAs. Radiolucencies were found in six hips and paraarticular ossifications in four. Migration of the cup with protrusion into the acetbulum occurred in one patient 3 years after THA. Four cups showed aseptic loosening within 3 to 7 years of surgery. No infection was recorded in this THA group. DISCUSSION Information on mid- and long-term outcomes of the use of cementless acetabular cups in the relevant literature is sparse. The Ultima cup is dealt with only in the report by Pazdírek et al., whose results are in agreement with ours, but involve a lower number of implanted cups and a shorter follow-up. In this study, loosening was recorded only in cups larger than 32 mm in diameter. In comparison with our group of cementless BMT acetabular components, the use of cementless Ultima cups gives better results at mid-term follow-up. CONCLUSIONS At 8.5-year follow-up, 88.9 % of the Ultima acetabular components were without radiographic signs of loosening. Attention should be paid primarily to THA patients with a thin wall acetabulum requiring a larger cup and a 32-mm liner.
منابع مشابه
A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.
We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions,...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملPrimary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.
BACKGROUND The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS A series of 173 consecutive, unselected cementless THA procedures using the Omnifit pros...
متن کاملResults of 3,668 primary total hip replacements
BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca
دوره 75 3 شماره
صفحات -
تاریخ انتشار 2008