Multiple harmonic compensation of Langmuir probes in rf discharges
نویسندگان
چکیده
We report on the use of an active Langmuir probe with three-harmonic compensation to diagnose rf discharge plasmas driven at 13.56 MHz. The plasma generates many harmonics on the fundamental, the first few being strongest. This gives a multi-harmonic rf voltage across the probe sheath that is removed by applying a rf signal to the probe that is matched both in amplitude and in phase for each harmonic. The probe I–V characteristic can then be analysed using dc theory. We show here that only when the rf harmonic amplitude approaches about 2Te is it necessary to compensate for that harmonic. For the commercial processing rig used this only occurs for the second harmonic at low pressures, <5 × 10−3 mbar. Here the addition of second-harmonic compensation shifts the probe I–V curve, making it markedly more positive than for fundamental-only compensation. Despite this the values obtained for the electron density ne and temperature Te changed by less than 10%. For most plasmas in which the harmonics have amplitudes below Te the use of fundamental-only compensation is adequate for all but the most precise measurements.
منابع مشابه
dc probe detection of phased EEDFs in RF discharges
Detection of non-Maxwellian electron energy distribution functions (EEDFs) by Langmuir probes in the presence of radiofrequency (RF) fluctuations in the plasma potential is possible if the probe is properly RF compensated. If the non-thermal electrons are created by wave acceleration, however, they usually are bunched at one phase of the RF. In this case, the usual method of forcing the probe t...
متن کاملMultichannel rf-compensated Langmuir probe array driven by a single bias supply
A multichannel Langmuir probe array driven by a single bias supply was constructed. For the probes to be used in harsh radio frequency ~rf! environments, the individual probe has a rf-compensation circuit. For simultaneously obtaining I – V curves from the probe array, shunt resistors were placed between the probe tips and the active terminal of the bias supply. The pickup signal due to the str...
متن کاملEvaluation of Langmuir probe ion density measurement in weakly ionized discharges using plasma oscillation probes and microwave interferometry
A comparison study is made of the classical theories of the determination of the ion density Ni from the ion current Ii to a cylindrical Langmuir probe vs bias voltage Vb in weakly ionized RF plasmas. A broad parameter range is examined in a commercial inductively coupled plasma (ICP). Accurate local electron density Ne values (Ne,MWI) obtained from Abel inversion of chord-averaged microwave in...
متن کاملLangmuir probe measurements in the intense RF field of a helicon discharge
Helicon discharges have extensively been studied for over 25 years both because of their intriguing physics and because of their utility in producing high plasma densities for industrial applications. Almost all measurements so far have been made away from the antenna region in the plasma ejected into a chamber where there may be a strong magnetic field (B-field) but where the radiofrequency (R...
متن کاملDouble and Triple Langmuir Probes Mea- Surements in Inductively Coupled Nitrogen Plasma
The double and triple Langmuir probe diagnostic systems with their necessary driving circuits are developed successfully for the characterization of laboratory built low pressure inductively coupled nitrogen plasma, generated by 13.56 MHz radio frequency (RF) power supply along with an automatic impedance matching network. Using the DC properties of these two probes, the discharge plasma parame...
متن کامل