Fifteen-year experience with the Bicarbon heart valve prosthesis in a single center
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate retrospectively the clinical performance of the Bicarbon valve (Sorin Biomedica Cardio, Saluggia, Italy) implanted at our center in Japan. METHODS Between January 1997 and December 2011, 415 patients in our institution were implanted with the Bicarbon valve. Nine of these recipients were excluded from the study because they had already undergone valve implantation and received a Bicarbon valve in a different position. The remaining patients were analyzed for evaluation of the postoperative clinical outcomes. Of the 406 patients (mean age 60.2 ± 11.7 years), 179 underwent aortic valve replacement (AVR), 149 mitral valve replacement (MVR), and 78 both aortic and mitral valve replacement (DVR). RESULTS There were 10 early deaths (2.5 %: 4 in the AVR group and 6 in the MVR group). Three hundred eighty-nine patients were followed up (95.8 % completeness of follow-up) with a mean follow-up of 6.6 ± 4.2 years overall (AVR 6.8 ± 4.2, MVR, 6.7 ± 4.4, and DVR 5.7 ± 3.4 years) and a cumulative follow-up of 2661 patient-years (1214, 1001, and 446 patient-years for AVR, MVR, and DVR, respectively). Ninety-nine patients died (3.7 % per patient-year: 22 valve-related and 77 valve-unrelated deaths). Survival at 10 years was 74.1 ± 4.0 % in the AVR group, 73.7 ± 4.2 % in the MVR group, and 61.0 ± 7.9 % in the DVR group. The linearized incidence of thromboembolic complications, bleeding complications, prosthetic valve endocarditis, paravalvular leaks, and sudden death in all patients was 0.5 %, 0.5 %, 0.2 %, 0.2 %, and 0.4 % per patient-year, respectively. The incidence of valve-related complications and reoperation was 1.6 % and 0.4 %, respectively. No other valve-related complications were observed. CONCLUSIONS The Bicarbon prosthetic heart valve has shown excellent clinical results and is associated with a low incidence of valve-related complications.
منابع مشابه
Clinical experience with the Bicarbon heart valve prosthesis
BACKGROUND We have previously reported mid-term results of a study, which ended in January 2000, on the Bicarbon valve. The study concluded that the valve showed excellent clinical results, associated with a low incidence of valve-related complications. In the present study, the same patients were prospectively followed for an additional 5 years. METHODS Forty-four patients had aortic valve r...
متن کاملBicarbon valve -- European multicenter clinical evaluation.
OBJECTIVE Fifteen collaborating centers in eight countries present their pooled experience with the new Bicarbon bileaflet valve. METHODS Between 4/90 and 4/96, 1351 patients, 806 males and 545 females, aged 10 to 83, mean 58.4 +/- 12.4, underwent valve implantation. OPERATIONS aortic valve replacement (AVR), 726; mitral valve replacement (MVR), 475; double valve replacement (DVR), 150. Add...
متن کاملDouble Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.
Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...
متن کاملTotally Supra-Annular Mechanical Valve: to provide good hemodynamic performance and good clinical outcomes
When replacing an aortic valve with a mechanical prosthesis it is essential to make the right decision, mine was on the Bicarbon Overline valve (SORIN Group). Bicarbon Overline is a bileaflet mechanical valve designed for a Totally Supra-Annular implant. The innovative design of the valve is highlighted by curved leaflets with an 80° opening angle and an aerofoil titanium housing profile leadin...
متن کاملA Single Voice Prosthesis Utilized For 17 Years
Introduction: Surgical procedures, especially total laryngectomy, have a profound adverse effect on the patient's physical, functional, as well as emotional health, and strongly decrease quality of life. Tracheoesophageal puncture is one of the most significant method that is widely performed successfully by physicians. Current valve technology enables long expiring duration; however, gen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -