Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis.
نویسندگان
چکیده
Cardiac index was measured using thoracic bioimpedance (CIbi) and thermodilution (CItd) in 19 patients with proven sepsis, undergoing artificial ventilation of the lungs. There was a poor correlation between the techniques (r = 0.36, 242 data sets, regression line CIbi = 0.16 CItd + 2.56 litre min-1 m-2). The overall bias (CItd-CIbi) was 1.69 litre min-1 m-2 with limits of agreement (precision) of +4.17 to -0.79 litre min-1 m-2. In individual patients the bias was from -0.46 to 4.56 litre min-1 m-2 with the limits of agreement from +/- 0.29 to +/- 2.55 litre min-1 m-2 around the bias values. The two techniques cannot be used interchangeably in this group of patients.
منابع مشابه
Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution.
The performance and reproducibility of the BoMED NCCOM3 thoracic electrical bioimpedance cardiograph (TEB) has been evaluated in volunteers and patients. In resting supine volunteers, we determined the coefficient of variability over short time periods (30 min) and over several days, and examined the effects of differences in electrode type and electrode placement. The mean (range) intra-subjec...
متن کاملSimultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound.
To evaluate the accuracy of two non-invasive techniques for cardiac output (CO) measurement, we have measured CO simultaneously by thoracic electrical bioimpedance (TEB), pulsed Doppler ultrasound (DU) and standard thermodilution methods (TD) under different clinical conditions. Measurements were made in 10 patients: (I) during steady state anaesthesia with controlled IPPV ventilation (n = 131)...
متن کاملAccuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study
Introduction Evaluation of accuracy, precision, and trending ability of cardiac index (CI) measurements using the Aesculon™ bioimpedance electrical cardiometry (Aesc) compared to the continuous pulmonary artery thermodilution catheter (PAC) technique before, during, and after cardiac surgery. Methods A prospective observational study with fifty patients with ASA 3-4. At six time points (T), m...
متن کاملAccuracy and Reliability of Non-invasive Cardiac Output: The Future in Cardiology?
A new generation of non-invasive cardiac output monitors provides an alternative to using conventional invasive methods such as thermodilution and direct Fick. The Bioz.com measures changes in thoracic electrical bioimpedance (TEB) of the descending aorta. The Innocor uses the principle of inert gas rebreathing. Simultaneous TEB and thermodilution cardiac output measurements were taken from 27 ...
متن کاملNon-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.
Cardiac output measured by thermodilution in 25 patients within 24 hours of acute myocardial infarction was compared with cardiac output measured by Doppler echocardiography (24 patients) and electrical bioimpedance (25 patients). The mean (range) cardiac outputs measured by Doppler (4.03 (2.2-6.0) 1/min) and electrical bioimpedance (3.79 (1.1-6.2) 1/min) were similar to the mean thermodilution...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 70 1 شماره
صفحات -
تاریخ انتشار 1993