A protocol for measuring pull-off stress of wound-treatment polymers.

نویسندگان

  • Vitaly O Kheyfets
  • Rita C Thornton
  • Mikala Kowal
  • Ender A Finol
چکیده

Skin wounds and burns compromise the body's natural barrier to bacteria and other pathogens. While many forms of wound dressings are available, polymeric films are advantageous for various reasons, ranging from the ease of application to durability. One common drawback of using polymeric films for a wound bandage is that the films tend to adhere to common inanimate objects. Patients spend hours in contact with soft and hard materials pressed against their skin, which, if the skin was dressed with a polymeric film, would inflict further wound damage upon body movement. In this work, we present a novel technique that allowed for measuring polymeric tackiness, after a long incubation period, with materials regularly encountered in a hospital or home setting, and soft fabrics. The polymers were exposed to an environment intended to simulate daily conditions and the technique is designed to perform multiple experiments simultaneously with ease. Four commercially available polymers (new-skin, no-sting skin-prep, skin shield, and Silesse) were tested as proof-of-concept to gather preliminary data for an overall assessment of wound treatment efficacy, resulting in the estimation of pull-off stress of the polymers from a specimen of porcine skin. Silesse did not reveal a measurable tackiness, no-sting skin-prep had the highest mean tackiness (13.8 kPa), while the mean tackiness between new-skin and skin shield was approximately equal (9.8 kPa vs. 10.1 kPa, respectively), p = 0.05. Future work on polymeric fluids for wound dressing applications should include tensile stress and dynamic viscosity estimations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Histopathological Investigation of the Effect of Ozonated Water on Skin Ulcer Healing Process in Isolation Stress Mouse Model

Background and Objective: Skin ulcers and their slow healing are considered as one of the important medical aspects. Nowadays, various antibiotics and materials are used to accelerate the wound healing process. One of the methods taken in the field of wound healing is using ozone. On the other hand, one of the factors that hurt the speed of wound healing is stress. Therefore, the present study ...

متن کامل

Potential Applications of Land Treatment Systems for Disinfectant-Rich Wastewater in Response to the COVID-19 Health Protocol: A Narrative Review

Introduction: The use of antiseptics and disinfectants in daily health protocols has a consequence of changing the quality of wastewater to be toxic to microbes. As a result, microbiological wastewater treatment has the potential to not be processed properly. To solve the problem of disinfectant-rich wastewater, a plant-based treatment method can be useful, the implementation of which is a land...

متن کامل

A Review of Laboratory Methods for Measuring Oxidative Stress

Introduction: Antioxidant defense system, including enzymatic and non-enzymatic antioxidants, protects cells from oxidative damage by neutralizing oxidant compounds. Increasing the production of oxidant species and decrease activity of antioxidant system causes oxidative stress. The role of oxidative stress in the pathogenesis of human diseases and strengthening of human antioxidant defense sys...

متن کامل

O-30: Evaluation of Anti-Mullerian Hormone (AMH) Cut-Off Levels in Serum and Follicular Fluid in Patients with and without Endocrinological Risk Factor in ART

Background: Assessment of AMH cut-off levels in serum and in follicle fluid (FF) for patients with (group 2, n=34) and without (group1, n= 96) endocrinological risk factors, such as ovarian hyperstimulation syndrome (OHSS) and polycystic ovary syndrome (PCOS), is clinically useful in optimising the treatment protocol. Materials and Methods: AMH was analysed in serum and FF of 130 infertile pati...

متن کامل

An Investigation on In-situ Strength and Bonding Strength of Polymer Modified Concretes (PMC) as Repair Overlays on Conventional Concrete Substrate

Polymer modified concrete (PMC) consists of Portland cement concrete with a polymer modifier. Its advantages are proper bonding strength to substrate concrete, high tensile and flexural strength and low amount of shrinkage and permeability. Using PMC overlays can be considered as a method for preservation of damaged concrete structures due to their suitable performance and durability. In this r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 136 7  شماره 

صفحات  -

تاریخ انتشار 2014