Cardiac Mean Electrical Axis in Thoroughbreds—Standardization by the Dubois Lead Positioning System
نویسندگان
چکیده
BACKGROUND Different methodologies for electrocardiographic acquisition in horses have been used since the first ECG recordings in equines were reported early in the last century. This study aimed to determine the best ECG electrodes positioning method and the most reliable calculation of mean cardiac axis (MEA) in equines. MATERIALS AND METHODS We evaluated the electrocardiographic profile of 53 clinically healthy Thoroughbreds, 38 males and 15 females, with ages ranging 2-7 years old, all reared at the São Paulo Jockey Club, in Brazil. Two ECG tracings were recorded from each animal, one using the Dubois lead positioning system, the second using the base-apex method. QRS complex amplitudes were analyzed to obtain MEA values in the frontal plane for each of the two electrode positioning methods mentioned above, using two calculation approaches, the first by Tilley tables and the second by trigonometric calculation. Results were compared between the two methods. RESULTS There was significant difference in cardiac axis values: MEA obtained by the Tilley tables was +135.1° ± 90.9° vs. -81.1° ± 3.6° (p<0.0001), and by trigonometric calculation it was -15.0° ± 11.3° vs. -79.9° ± 7.4° (p<0.0001), base-apex and Dubois, respectively. Furthermore, Dubois method presented small range of variation without statistical or clinical difference by either calculation mode, while there was a wide variation in the base-apex method. CONCLUSION Dubois improved centralization of the Thoroughbreds' hearts, engendering what seems to be the real frontal plane. By either calculation mode, it was the most reliable methodology to obtain cardiac mean electrical axis in equines.
منابع مشابه
Comparison of Dubois and Base - Apex Lead Methods to Calculate QRS Angle ( Mean Electrical Axis ) in Thoroughbreds
This study evaluated electrocardiographic profile of 53 Thoroughbreds, clinically healthy, with ages ranging 2-7 years old, 38 males and 15 females, all reared at the São Paulo Jockey Club, Brazil. Two electrocardiograms were recorded in each horse, and the results of mean electrical axis in frontal plane, obtained by measuring QRS complexes amplitude, were compared using two electrode position...
متن کاملEffects of tramadol on electrocardiogram, mean electrical axis and respiration in Kagani goats (Capra hircus)
The effects of tramadol on electrocardiogram (ECG), mean electrical axis and respiratory rates were studied in adult kagani goats after intramuscular administration of tramadol at 1 mg/kg b.wt. as a prelude to its clinical use as an analgesic in veterinary practice. The ECG was monitored by standard bipolar leads and discernible electrocardiographic features were observed in lead II. The normal...
متن کاملLeast Squares Techniques for GPS Receivers Positioning Filter using Pseudo-range and Carrier Phase Measurements
In present study, using Least Squares (LS) method, we determine the position smoothing in GPS single-frequency receiver by means of pseudo-range and carrier phase measurements. The application of pseudo-range or carrier phase measurements in GPS receiver positioning separately can lead to defects. By means of pseudo-range data, we have position with less precision and more distortion. By use of...
متن کاملPositioning the first short axis slice for ventricular volume analysis
Background Ventricular volumetrics play a fundamental role in cardiac magnetic resonance imaging analysis. Accuracy is of course paramount, and thus crucial that the image data set is precise.This poster defines the correct positioning of the short axis (SA) cinematographic images, and the rationale behind it. Since most volume studies concentrate on the left ventricle (LV) slice positioning fo...
متن کاملDelay Spoofing Reduction in GPS Navigation System based on Time and Transform Domain Adaptive Filtering
Due to widespread use of Global Positioning System (GPS) in different applications, the issue of GPS signal interference cancelation is becoming an increasing concern. One of the most important intentional interferences is spoofing signals. An effective interference (delay spoof) reduction method based on adaptive filtering is developed in this paper. The principle of method is using adaptive f...
متن کامل