The respiratory pressure—abdominal volume curve in a porcine model

نویسندگان

  • Adrian Regli
  • Bart Leon De Keulenaer
  • Bhajan Singh
  • Lisen Emma Hockings
  • Bill Noffsinger
  • Peter Vernon van Heerden
چکیده

BACKGROUND Increasing intra-abdominal volume (IAV) can lead to intra-abdominal hypertension (IAH) or abdominal compartment syndrome. Both are associated with raised morbidity and mortality. IAH can increase airway pressures and impair ventilation. The relationship between increasing IAV and airway pressures is not known. We therefore assessed the effect of increasing IAV on airway and intra-abdominal pressures (IAP). METHODS Seven pigs (41.4 +/-8.5 kg) received standardized anesthesia and mechanical ventilation. A latex balloon inserted in the peritoneal cavity was inflated in 1-L increments until IAP exceeded 40 cmH2O. Peak airway pressure (pPAW), respiratory compliance, and IAP (bladder pressure) were measured. Abdominal compliance was calculated. Different equations were tested that best described the measured pressure-volume curves. RESULTS An exponential equation best described the measured pressure-volume curves. Raising IAV increased pPAW and IAP in an exponential manner. Increases in IAP were associated with parallel increases in pPAW with an approximate 40% transmission of IAP to pPAW. The higher the IAP, the greater IAV effected pPAW and IAP. CONCLUSIONS The exponential nature of the effect of IAV on pPAW and IAP implies that, in the presence of high grades of IAH, small reductions in IAV can lead to significant reductions in airway and abdominal pressures. Conversely, in the presence of normal IAP levels, large increases in IAV may not affect airway and abdominal pressures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Matching positive end-expiratory pressure to intra-abdominal pressure improves oxygenation in a porcine sick lung model of intra-abdominal hypertension

INTRODUCTION Intra-abdominal hypertension (IAH) causes atelectasis, reduces lung volumes and increases respiratory system elastance. Positive end-expiratory pressure (PEEP) in the setting of IAH and healthy lungs improves lung volumes but not oxygenation. However, critically ill patients with IAH often suffer from acute lung injury (ALI). This study, therefore, examined the respiratory and card...

متن کامل

Comparison of the Effects of Prone and Supine Positions on Abdominal Distention in the Premature Infants Receiving Nasal Continuous Positive Airway Pressure (NCPAP)

Background: Premature infants with respiratory distress syndrome (RDS) are in dire need of respiratory support with a ventilator. However, the high tidal volume of mechanical ventilation may cause lung injury, and researchers have been concerned with the use of nasal continuous positive airway pressure (NCPAP). NCPAP has concomitant side effects, such as abdominal distention, which might disrup...

متن کامل

Blood oxygenation during hyperpressure intraperitoneal fluid administration in a rabbit model of severe liver injury: Evaluation of a novel concept for control of pre-hospital liver bleeding

Oxygen is an essential part of the most important metabolic pathways in aerobic organisms. Oxygen delivery is merely dependent on blood, rendering blood loss a devastating event. Traumatic pre-hospital liver bleeding is a major cause of early trauma deaths in human and animals, with no established therapeutic method yet. Increasing intra-abdominal pressure (IAP) has been shown to reduce liver b...

متن کامل

Endexpiratory lung volume measurement correlates with the ventilation/perfusion mismatch in lung injured pigs

BACKGROUND In acute respiratory respiratory distress syndrome (ARDS) a sustained mismatch of alveolar ventilation and perfusion (VA/Q) impairs the pulmonary gas exchange. Measurement of endexpiratory lung volume (EELV) by multiple breath-nitrogen washout/washin is a non-invasive, bedside technology to assess pulmonary function in mechanically ventilated patients. The present study examines the ...

متن کامل

Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study

INTRODUCTION The aim of this study was to evaluate dynamic indices of fluid responsiveness in a model of intra-abdominal hypertension. METHODS Nine mechanically-ventilated pigs underwent increased intra-abdominal pressure (IAP) by abdominal banding up to 30 mmHg and then fluid loading (FL) at this IAP. The same protocol was carried out in the same animals made hypovolemic by blood withdrawal....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017