Continuous measurement of blood gases in vivo by mass spectrometry.

نویسندگان

  • P Foëx
  • G Burt
  • P Maynard
  • W A Ryder
  • C E Hahn
چکیده

Continuous analysis of oxygen and carbon dioxide tension in the blood phase, over periods of 4-5 h, was carried out in the pulmonary artery (93 determinations in six anesthetized dogs) and in the aorta (29 determinations in four anaesthetized dogs). Silastic-covered stainless steel catheters attached to a mass spectrometer were used. The mass spectrometer signals were linearly related to the blood-gas tensions measured by conventional analysis. The mass spectrometer signals were calibrated in vivo by exposing the animals to high and low oxygen and carbon dioxide tension. With such in vivo calibration the slopes of the straight line regressions for mass spectrometer PO2 or PCO2 on PO2 or PCO2 by conventional analysis were comprised between 0.944 and 1.031 while the standard error of the slopes were between 0.019 and 0.031. Deliberate reductions of cardiac output had little effect on the mass spectrometer readings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical catheter for continuous blood gas measurement by mass spectrometry.

A new Teflon catheter for continuous in vivo measurement of blood gases by mass spectrometry has an outer diameter of 0.032 in. and can be inserted through percutaneous puncture with an 18-gauge needle. Response time (63% of a total change) is 40 s for oxygen and 65 s for carbon dioxide. When calibrated in analyzed gas at 37 degrees C, the catheter-mass spectrometer system has been shown to ana...

متن کامل

The scope of mass spectrometry in clinical chemistry.

Several aspects of mass spectrometry and gas chromatography-mass spectrometry are reviewed, including ionization methods, repetitive scanning, selected ion monitoring, and stable isotope measurement. I discuss the application of these and other mass spectrometry methods to the investigation of compound classes relevant to clinical chemistry, to the assessment of inborn errors of metabolism, and...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

Real-time trace gas sensing of ethylene, propanal and acetaldehyde from human skin in vivo.

Trace gases emitted by human skin in vivo are monitored non-invasively and in real time using laser-based photoacoustic detection and proton-transfer reaction mass spectrometry. A small quartz cuvette is placed on the skin to create a headspace from which a carrier gas transports the skin emissions to the detection systems. The transparency of quartz to ultraviolet radiation (UVR) allows invest...

متن کامل

Real-time monitoring of propofol in expired air in humans undergoing total intravenous anesthesia.

BACKGROUND The physicochemical properties of propofol could allow diffusion across the alveolocapillary membrane and a measurable degree of pulmonary propofol elimination. The authors tested this hypothesis and showed that propofol can be quantified in expiratory air and that propofol breath concentrations reflect blood concentrations. This could allow real-time monitoring of relative changes i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 51 11  شماره 

صفحات  -

تاریخ انتشار 1979