Scintigraphic Assessment of Deposition of Radiolabeled Fluticasone Delivered from a Nebulizer and Metered Dose Inhaler in 10 Healthy Dogs
نویسندگان
چکیده
BACKGROUND Aerosolized medications are increasingly being used to treat respiratory diseases in dogs. No previous studies assessing respiratory tract deposition of radiolabeled aerosols have been performed in conscious dogs. HYPOTHESIS/OBJECTIVES Assess respiratory tract deposition of radiolabeled, inhalant corticosteroid (fluticasone propionate labeled with 99m Tc) delivered from a nebulizer and metered dose inhaler (MDI) to healthy dogs. ANIMALS Ten healthy Foxhounds. METHODS Prospective, randomized, cross-over pilot study. Initial inhalation method (nebulizer or MDI) was randomly assigned. Treatments were crossed over after a 7-day washout period. Treatments initially were performed using sedation. Dogs were imaged using 2-dimensional planar scintigraphy, with respiratory tract deposition quantified by manual region-of-interest analysis. Deposition calculated as percentage of delivered dose. Six of 10 dogs were randomly selected and reassessed without sedation. RESULTS Inhalation method had significant effect on respiratory tract deposition (P = 0.027). Higher deposition was achieved by nebulization with mean deposition of 4.2% (standard deviation [SD], 1.4%; range, 1.9-6.1%); whereas MDI treatment achieved a mean of 2.3% (SD, 1.4%; range, 0.2-4.2%). Nebulization achieved higher respiratory tract deposition than MDI in 7 of 10 dogs. No statistical difference (P = 0.68) was found between mean respiratory tract deposition achieved in dogs when unsedated (3.8%; SD, 1.5%) or sedated (3.6%; SD, 1.7%). CONCLUSIONS AND CLINICAL IMPORTANCE Study confirms respiratory tract deposition of inhalant medications delivered from a nebulizer and MDI in healthy dogs, breathing tidally with and without sedation. Respiratory tract deposition in these dogs was low compared to reported deposition in adult humans, but similar to reported deposition in children.
منابع مشابه
Scintigraphic comparison of budesonide deposition from two dry powder inhalers.
Chlorofluorocarbons (CFCs), used in metered dose inhalers (MDIs), have been identified as being deleterious to the environment leading to a ban on their production. Dry powder inhalers (DPIs) are a widely used alternative to MDIs. One disadvantage of DPIs is that in vivo lung deposition can be influenced by the patient's inspiratory flow rate. The ASTA Medica multi-dose dry powder inhaler (AM-M...
متن کاملAirway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers.
Many different metered-dose inhalation devices are becoming available for the treatment of airway diseases. Each of these inhalers differs in its delivery characteristics. An assessment of the efficacy of drug delivery by these inhalers is essential, in view of their therapeutic use. A review of the literature on the relationship between airway deposition and airway effects of drugs delivered f...
متن کاملDelivery of propellant soluble drug from a metered dose inhaler.
The deposition of particulate suspensions delivered from a metered dose inhaler has been investigated extensively. The distribution of propellant, delivered from a metered dose inhaler, was studied by radiolabelling it with technetium-99m hexamethylpropyleneamine oxime. Andersen sampler measurements indicated that half of the dose was associated with particles in the size range 0.5-5 microns di...
متن کاملA comparison of responses to albuterol delivered by two aerosol devices.
Nineteen outpatients with stable obstructive pulmonary disease (mean forced expiratory volume in one second [FEV1], 1.00 + 0.10 L) were evaluated for airway response to albuterol (salbutamol) administered by metered-dose inhaler and Bosch ultrasonic nebulizer (BUSN). Albuterol administered by metered-dose inhaler but not by nebulizer caused a significant increase in FEV1 and the mean forced exp...
متن کاملFacemasks and aerosol delivery in vivo.
It has been shown in vitro that even a small air leak in the facemask can drastically reduce the efficiency of drug delivery. In addition, it has been shown that drug deposition on the face does significantly add to overall drug loss and has the potential of local side effects. The aim of this study is therefore to verify these findings in vivo. Eight asymptomatic recurrently wheezy children, a...
متن کامل