Volume Responsiveness in Critically Ill Patients
نویسندگان
چکیده
odern resuscitation has changed since the advent of goaldirected therapy. Today, practitioners providing fluid resuscitation are cognizant of the danger associated with volume depletion while being aware of the morbidity of volume overload.1 Thus, fluid resuscitation must be rapid, precise, and individually tailored to each patient based on reliable data.2 Critically ill patients have a mixture of intravascular volume depletion, low systemic vascular resistance, and decreased cardiac output, which makes responses to attempts at volume resuscitation difficult to predict. As a result, despite initial attempts at fluid resuscitation, persistent hypotension is common and poses the dilemma of whether the patient should receive additional fluid boluses, a vasopressor, or a positive inotropic agent. Traditionally, resuscitation was guided by static measurements, such as central venous pressure, which was thought to determine the patient’s “intravascular volume.”1 These static measurements have been shown to be unreliable predictors of a patient’s ability to positively respond to volume expansion.3 Clinicians have increasingly relied on fluid responsiveness, defined as an increase in cardiac output by 15% following a 500-mL fluid bolus given over 10 minutes, to guide the resuscitation process. Several minimally invasive methods have been used to determine whether a patient is fluid responsive, including pulse counter analysis,4 transpulmonary thermodilution,5 and reactance.6 All of these methods have shown promise in evaluation of the volume status of septic patients; however, bedside sonography has also emerged as a useful tool for evaluating cardiac function in critically ill patients.7 The echocardiographic methods described below are entirely noninvasive, provide real-time data, can be taught reasonably quickly, and can be repeated frequently until desirable clinical outcomes are achieved. This article will review 3 methods aimed at predicting volume responsiveness in critical ill patients: (1) measurement of the caval index; (2) measurement of cardiac output with passive leg raising; and (3) measurement of common carotid artery (CCA) blood flow with passive leg raising.8–10 These latter techniques enable bedside clinicians to determine changes in blood flow in the left ventricular outflow tract (LVOT) and aorta in response to manipulations of right ventricular preload by passive leg raising, thus predicting the response to a fluid bolus without exposing the patient to potentially harmful hypervolemia.11 David Evans, MD, Giovanna Ferraioli, MD, John Snellings, MD, Alexander Levitov, MD
منابع مشابه
Pharmacokinetic Behavior of Theophylline following PEEP in Critically Ill Patients with Acute Lung Injury
The effect of Positive End Expiratory Pressure (PEEP) on the hepatic elimination of low to moderate extraction ratio drugs has not been clearly defined. We prospectively investigated the effect of PEEP on the clearance of theophylline in 30 (20 males and 10 females) intubated critically ill adult patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS). The Mean (±SD) age ...
متن کاملEchocardiographic Assessment of Preload Responsiveness in Critically Ill Patients
Fluid challenges are considered the cornerstone of resuscitation in critically ill patients. However, clinical studies have demonstrated that only about 50% of hemodynamically unstable patients are volume responsive. Furthermore, increasing evidence suggests that excess fluid resuscitation is associated with increased mortality. It therefore becomes vital to assess a patient's fluid responsiven...
متن کاملPharmacokinetic Behavior of Theophylline following PEEP in Critically Ill Patients with Acute Lung Injury
The effect of Positive End Expiratory Pressure (PEEP) on the hepatic elimination of low to moderate extraction ratio drugs has not been clearly defined. We prospectively investigated the effect of PEEP on the clearance of theophylline in 30 (20 males and 10 females) intubated critically ill adult patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS). The Mean (±SD) age ...
متن کاملThe effects of foot massage on physiologic indicators in critically ill patients
The perpuse of this research is to determine the effect of foot massage on physiologic indicators including pulse, respiration and mean arterial pressure. The hypothesis of this research is that foot massage decreases the patient´s heart rate, respiratory rate and mean arterial pressure. This research is a quasiexperimental study and a self-control clinical trial with repeated measures in witch...
متن کاملCan Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review
Introduction. We systematically evaluated the use of transthoracic echocardiography in the assessment of dynamic markers of preload to predict fluid responsiveness in the critically ill adult patient. Methods. Studies in the critically ill using transthoracic echocardiography (TTE) to predict a response in stroke volume or cardiac output to a fluid load were selected. Selection was limited to E...
متن کاملMetformin Treatment in Hyperglycemic Critically Ill Patients: Another Challenge on the Control of Adverse Outcomes
New-onset hyperglycemia in patients admitted to intensive care units increases the risk of morbidity and mortality. Insulin resistance is frequently seen in the treatment of stress-induced hyperglycemia. Metformin, an oral anti-hyperglycemic agent, may introduce a new treatment protocol in critically ill patients with insulin-resistance hyperglycemia. Fifty-one non-diabetic traumatized patients...
متن کامل