OBJECTIVES The goal of this study was to evaluate whether quantitation of thrombus burden with transesophageal echocardiography (TEE) can help risk-stratify patients undergoing thrombolysis of prosthetic valve thrombosis (PVT). BACKGROUND Thrombolytic therapy of PVT has an unpredictable risk of embolization and complications. METHODS An international registry of patients with suspected PVT undergoing two-dimensional/Doppler and TEE before thrombolysis was established. All TEE studies were reviewed and quantitated by a single observer blinded to all data. RESULTS From 1985 to 2001, 107 patients (71 females; age 24 to 86 years) from 14 centers (6 in the U.S.) were identified. The majority of cases involved the mitral valve (79 mitral, 13 aortic, and 15 tricuspid). Hemodynamic success rate was achieved in 85% and was similar across valves. Overall complications were observed in 17.8%, and death in 5.6%. Predictors of complications were: New York Heart Association (NYHA) functional class, presence of shock, sinus tachycardia, hypotension, previous history of stroke, thrombus extension beyond the valve ring, and thrombus area. Multivariate analysis demonstrated that two variables were independent predictors of complications: thrombus area by TEE (odds ratio [OR] 2.41 per 1 cm2 increment, 95% confidence interval [CI] 1.12 to 5.19) and prior history of stroke (OR 4.55, 95% CI 1.35 to 15.38). A thrombus area <0.8 cm2 identified patients at lower risk for complications from thrombolysis, irrespective of NYHA functional class. CONCLUSIONS In PVT, the thrombus size imaged with TEE is a significant independent predictor of outcome. Transesophageal echocardiography can identify low-risk groups for thrombolysis irrespective of symptom severity and is therefore recommended in the management of prosthetic valve thrombosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

Intravenous thrombolytic treatment of mechanical prosthetic valve thrombosis: a study using serial transesophageal echocardiography.

OBJECTIVE We analyzed the results of intravenous thrombolytic treatment under transesophageal echocardiographic (TEE) guidance in prosthetic valve thrombosis. BACKGROUND Thrombotic occlusion of prosthetic valves continues to be an uncommon but serious complication. Intravenous thrombolytic treatment has been proposed as an alternative to surgical intervention. METHODS In a four-year period,...

متن کامل

Bioprosthetic mitral valve thrombosis. Importance of transesophageal echocardiography in the diagnosis and follow-up after treatment.

OBJECTIVE To report the clinical and echocardiographic findings of bioprosthetic mitral valve thrombosis and the value of transesophageal echocardiography (TEE) in its diagnosis and monitoring of thrombolysis. METHODS One hundred and eleven patients with mitral bioprostheses underwent TEE, and 4 out of 7 suspected of having a thrombus on these prostheses were included in the study (mean age =...

متن کامل

A mass obstructing mechanical prosthetic heart valve: thrombus or pannus?

Mahajan K, et al. BMJ Case Rep 2017. doi:10.1136/bcr-2017-219573 Description Mechanical prosthetic valve obstruction carries a significant morbidity and mortality, if not treated urgently. Most notable causes of an acquired obstruction include thrombosis and pannus formation. It is critically important to exclude isolated pannus, since thrombolysis is an effective and rapid treatment option in ...

متن کامل

Live/real time three-dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation.

Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2004