Combined use of non-thoracotomy cardioverter defibrillators and endocardial pacemakers.

نویسندگان

  • H H Noguera
  • A O Peralta
  • R M John
  • F J Venditti
  • D T Martin
چکیده

OBJECTIVE To study the potential interactions in patients with endocardial permanent pacemakers and non-thoracotomy implantable cardioverter defibrillator (ICD) systems. DESIGN Case series and cohort study. SETTING Tertiary referral centre. PATIENTS Fifteen consecutive patients with both endocardial pacemakers (12 dual chamber and three single chamber) and non-thoracotomy ICD systems. MAIN OUTCOME MEASURES Detection inhibition of induced ventricular fibrillation; double counting; and pacemaker function after shocks. In the evaluation of detection inhibition, 124 VF inductions were analysed for detection duration compared with induced VF episodes in controls with an ICD but without a pacemaker. RESULTS Two patients (13%) showed detection inhibition of VF and required pacemaker system change at the time of the ICD implant. With the final lead position, despite frequent pacemaker undersensing of VF, ICD detection of VF was not inhibited during any induction, and neither initial detection nor redetection times for VF were different from controls. Double/triple counting of pacemaker artefact and evoked electrogram was noted in three patients (20%). In two, this was remedied during the implantation procedure, and in the other it was abolished when amiodarone treatment was discontinued. Pacemaker function was affected by ICD discharges in two patients, one who showed postshock atrial undersensing and loss of capture, and another whose pacemaker reverted to VVI mode. CONCLUSIONS When careful testing is performed at implantation to detect and remedy device interactions, non-thoracotomy ICD treatment and endocardial pacemakers can be used safely in combination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Placement of an Implantable Cardioverter Defibrillator Thorough a Transatrial Approach. A Case Report

Thrombosis of the superior vena cava is not frequent, but its appearance makes difficult the way for the implantation of pacemakers and defibrillators. There are alternatives when endovascular and epicardium vias cannot be used. However, some implantations of catheters of defibrillators via transatrial through minimal thoracotomy with good results at long-term and with an adequate threshold of ...

متن کامل

Implantable Cardiac Devices

Electrical cardiac pacing for the management of bradyarrhythmias was first described in 1952, and permanent transvenous pacing devices were introduced into clinical practice in the early 1960s. The first devices for endocardial defibrillation were implanted in surviving victims of sudden cardiac death in 1980. Implanted electrical devices for the management of cardiac dysrhythmias have changed ...

متن کامل

Reuse Potential of Pacemakers and Implantable Cardioverter-defibrillators - Some Real World Data

Patients who survive either ventricular fibrillation or sustained ventricular tachycardia carry a high risk of further episodes, which could be fatal. Anti-arrhythmic drugs were the standard treatment for patients with malignant ventricular arrhythmias, but despite using the best appropriate medical treatment, arrhythmia recurrence rates remain high at 40-50% at five years. Implantable cardiove...

متن کامل

Types of pacemakers and their complications.

1. Implantable pulse generators with endocardial or myocardial electrodes for long-term or permanent use. 2. External, miniaturized, transistorized, patientportable, battery-powered, pulse generators with exteriorized electrodes for temporary transvenous endocardial or transthoracic myocardial pacing. 3. Console batteryor AC-powered cardiovertors, defibrillators, or monitors with high-current e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 1997