Diagnostic performance of 3D TSE MRI versus 2D TSE MRI of the knee at 1.5 T, with prompt arthroscopic correlation, in the detection of meniscal and cruciate ligament tears*
نویسندگان
چکیده
OBJECTIVE To compare the diagnostic performance of the three-dimensional turbo spin-echo (3D TSE) magnetic resonance imaging (MRI) technique with the performance of the standard two-dimensional turbo spin-echo (2D TSE) protocol at 1.5 T, in the detection of meniscal and ligament tears. MATERIALS AND METHODS Thirty-eight patients were imaged twice, first with a standard multiplanar 2D TSE MR technique, and then with a 3D TSE technique, both in the same 1.5 T MRI scanner. The patients underwent knee arthroscopy within the first three days after the MRI. Using arthroscopy as the reference standard, we determined the diagnostic performance and agreement. RESULTS For detecting anterior cruciate ligament tears, the 3D TSE and routine 2D TSE techniques showed similar values for sensitivity (93% and 93%, respectively) and specificity (80% and 85%, respectively). For detecting medial meniscal tears, the two techniques also had similar sensitivity (85% and 83%, respectively) and specificity (68% and 71%, respectively). In addition, for detecting lateral meniscal tears, the two techniques had similar sensitivity (58% and 54%, respectively) and specificity (82% and 92%, respectively). There was a substantial to almost perfect intraobserver and interobserver agreement when comparing the readings for both techniques. CONCLUSION The 3D TSE technique has a diagnostic performance similar to that of the routine 2D TSE protocol for detecting meniscal and anterior cruciate ligament tears at 1.5 T, with the advantage of faster acquisition.
منابع مشابه
Accuracy of MRI in Comparison with Arthroscopic Findings in the Diagnosis of Anterior Cruciate Ligament and Meniscus Tears
Background: Magnetic resonance imaging (MRI) is of great aid in the diagnosis of knee lesions. Nevertheless, arthroscopy has remained the reference standard for the diagnosis of internal derangements of the knee, against which alternative diagnostic modalities should be compared. This study was designed to assess the value of MRI and clinical examination in the diagnosis of Anterior Cruciate Li...
متن کاملAccuracy of MRI in comparison with clinical and arthroscopic findings in ligamentous and meniscal injuries of the knee.
Rapidly progressing medical technology sometimes obscures the importance of history and physical examination. This study was designed to assess the value of MRI and clinical examination in the diagnosis of ligamentous and meniscal knee injuries in comparison with arthroscopic findings. In the year 2003-2004, we conducted a prospective, single blind study to assess ligamentous and meniscal injur...
متن کاملDiagnostic performance of CUBE MRI sequences of the knee compared with conventional MRI.
AIM To evaluate the efficacy and efficiency of three-dimensional (3D) fast spin-echo (FSE) with variable flip angle ("CUBE") magnetic resonance imaging (MRI) in knee imaging as compared with conventional MRI. MATERIALS AND METHODS Twenty-nine patients (single knee) with joint injuries of varying degrees were enrolled in this study between January, 2011 and December, 2011. All patients underwe...
متن کاملبررسی ارزش تشخیصی معاینات بالینی در مقایسه با آرتروسکوپی در تشخیص ضایعات تحت حاد داخل مفصل زانو
Introduction & Objective: Rapidly progressing medical technology sometimes obscures the importance of physical examination. This study was designed to assess the value of clinical examination in the diagnosis of ligamentous and meniscal knee injuries in comparison with arthroscopic findings. Materials & Methods: Between 2006-2008 we conducted an observational study to assess intraarticular i...
متن کاملارزیابی حساسیت و ویژگی MRI در مقایسه با آرتروسکوپی در ضایعات زانو
Background: The knee is the most commonly injured joint. The internal components of the knee include the meniscuses, the anterior cruciate ligament (ACL) and posterior cruciate ligaments (PCL). Magnetic resonance imaging (MRI) is now used widely because of its high accuracy and noninvasiveness. Our objective was to diagnose internal knee component injuries by MRI and compare its diagnostic valu...
متن کامل