Reliability in Full Leg Standing Radiographs for Total Knee Arthroplasty Pre-Operative Planning
ثبت نشده
چکیده
One of the most common modes of failure for total knee arthroplasty is aeseptic loosening of the components [2]. Aeseptic loosening failure of both the femoral and tibial components has been shown to occur if the alignment of the knee occurs outside of ± 3° from the mechanical alignment in the coronal plane [3]. Proper mechanical alignment of the knee is dependent on the correct proximal varus/valgus tibia resection that is calculated from FLS radiographs. This study compares measurements made for tibial varus/valgus alignment from FLS radiographs to measurements made from anterior-posterior radiographs of just the tibia in an effort to show that FLS studies are accurate and robust enough, despite rotation that can be introduced due to the patient’s full leg deformity, to be used to correctly account for tibia bows in pre-operative planning for total knee arthroplasty.
منابع مشابه
The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum
Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...
متن کاملCoronal Alignment of the Lower Limb and the Incidence of Constitutional Varus Knee in Korean Females
PURPOSE In total knee arthroplasty (TKA), it is important to restore neutral mechanical alignment. The purpose of this study was to assess whether the lower limb alignment is neutral in healthy Korean females and investigate the incidence of constitutional varus knees among them. MATERIALS AND METHODS Weight-bearing full-leg standing radiographs were obtained from 118 healthy females between ...
متن کاملA computer-assisted, tibia-first technique for improved femoral component rotation in total knee arthroplasty
Background The use of navigation for total knee arthroplasty (TKA) improves limb alignment in the coronal and sagittal planes. However, similar improvements in femoral and tibial component rotation have not yet been realized using currently available systems. Methods We developed a modified navigated TKA technique in which femoral rotation was set using the resected tibial plane as the refere...
متن کاملUsing the Anatomical Axis as an Alternative to the Mechanical Axis to Assess Knee Alignment.
The treatment of knee osteoarthritis and the preparation for total knee arthroplasty require repetitive imaging to guide preoperative planning and operative technique. Full-length standing anteroposterior images are the gold standard in assessing the alignment of the limb via the measurement of the mechanical axis of the knee. The anatomical axis can be obtained from a more limited image of the...
متن کاملValidity of an oblique posterior condylar radiographic view for revision total knee arthroplasty.
We have previously developed a radiographic technique, the oblique posterior condylar view, for assessment of the posterior aspect of the femoral condyles after total knee arthroplasty. The purpose of this study was to confirm the validity of this radiographic view based upon intra-operative findings at revision total knee arthroplasty. Lateral and oblique posterior condylar views were performe...
متن کامل