TITLE: Improved Diagnosis of Infection Associated to Osteosynthesis by Use of Sonication

نویسندگان

  • Maysa Harumi Yano
  • Giselle Burlamaqui Klautau
  • Cely Barreto da Silva
  • Stanley Nigro
  • Osmar Avanzi
  • Marcelo Tomanink Mercadante
  • Mauro Jose Costa Salles
  • Mauro Jose Costa
چکیده

20 Previous studies have shown that sonication-fluid cultures from removed devices improved the 21 microbiological diagnosis of orthopedic implant-associated infections; however, few of these 22 investigations have applied sonication to the removed fracture-fixation devices to evaluate its 23 utility as an adjunctive diagnostic tool for osteosynthesis-associated infection (OAI). We 24 compared sonication fluid to conventional tissue cultures from 180 subjects with different sizes 25 plates and screws (n=156), spinal implants (n=26) and intra-medullary nails (n=3), of which 125 26 and 55 subjects had OAI and noninfected osteosynthesis (NIO), respectively. The sensitivity for 27 detecting OAI was 90.4% for sonication-fluid culture and 56.8% for periprosthetic tissue cultures 28 (P < 0.05), and specificities were 90.9% and 96.4%, respectively. Sonication-fluid culture 29 detected more pathogens than peri-implant tissue culture (113 vs 71; P < 0.001), while 30 polymicrobial infections were diagnosed by sonication-fluid cultures and tissue cultures in 31 20.8% and 8% (P < 0.001), respectively. Microbiologic diagnosis was achieved exclusively by 32 sonication-fluid cultures on 47 (90.4%) subjects, and among them, 18 (38.3%) had previously 33 received antibiotics, whether on five (9.6%) infected subjects, tissue culture was positive and the 34 sonication-fluid culture was negative. Among 39 (31.2%) OAI cases receiving antibiotics, 35 identification of organisms occurred in 38.5% and 82.1% on tissue culture and sonication-fluid 36 culture, respectively (P < 0.049). We demonstrated that sonication-fluid culture from removed 37 osteosynthesis has the potential for improving the microbiological diagnosis of OAI. 38

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved diagnosis of infection associated with osteosynthesis by use of sonication of fracture fixation implants.

Previous studies have shown that sonication fluid cultures from removed orthopedic devices improved the microbiological diagnosis of orthopedic implant-associated infections; however, few of these investigations have applied sonication to the removed fracture fixation devices to evaluate its utility for the diagnosis of osteosynthesis-associated infection (OAI). We compared sonication fluid to ...

متن کامل

PCR-hybridization after sonication improves diagnosis of implant-related infection

PURPOSE We wanted to improve the diagnosis of implant-related infection using molecular biological techniques after sonication. METHODS We studied 258 retrieved implant components (185 prosthetic implants and 73 osteosynthesis implants) from 126 patients. 47 patients had a clinical diagnosis of infection (108 components) and 79 patients did not (150 components). The fluids from sonication of ...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

Cost-benefit analysis of antibiofilm microbiological techniques for peri-prosthetic joint infection diagnosis

BACKGROUND Implant-related infections, including those of peri-prosthetic joint (PJIs), osteosynthesis and other biomaterials, are biofilm-related. Pathogen identification is considered the diagnostic benchmark; however, the presence of bacterial biofilms makes pathogen detection with traditional microbiological techniques only partially effective. To improve microbiological diagnostic accuracy...

متن کامل

Improved diagnosis of orthopedic implant-associated infection by inoculation of sonication fluid into blood culture bottles.

Sonication improved the diagnosis of orthopedic implant-associated infections (OIAI). We investigated the diagnostic performance of sonication fluid inoculated into blood culture bottles in comparison with that of intraoperative tissue and sonication fluid cultures. Consecutive patients with removed orthopedic hardware were prospectively included and classified as having OIAI or aseptic failure...