First clinical evaluation of a new long-term subconjunctival glucose sensor.
نویسندگان
چکیده
BACKGROUND To evaluate the feasibility of an implantable subconjunctival glucose monitoring system (SGMS) for glucose monitoring in humans, we investigated the in vivo performance of the sensor in a clinical trial with five patients. METHODS The new SGMS consists of an implantable ocular mini implant (OMI) and a hand-held fluorescence photometer. The implantable subconjunctival glucose sensor is composed of a fluorescence resonance energy transfer system based on Concanavalin A chemistry, embedded in a nelfilcon polymer hydrogel disk. Blood glucose changes in humans were induced by oral glucose intake and insulin injections. RESULTS The in vivo response of the new SGMS was tested in a first human clinical study with five diabetes patients. The OMI was well tolerated in the eyes of the patients. The SGMS exhibited high correlation coefficients (>0.88) with blood glucose changes and a good stability of the sensor response to glucose for the study period of 2 weeks. Lag times were in the range of 5-10 min. A total of 98% of all data pairs was in the clinical acceptable ranges A and B of the consensus error grid. CONCLUSIONS For the first time, the possibility to measure glucose in vivo in the subconjunctival interstitial fluid for a period of 2 weeks was demonstrated in a human clinical trial.
منابع مشابه
Blood glucose self-monitoring with a long-term subconjunctival glucose sensor.
BACKGROUND To evaluate the feasibility of an implantable subconjunctival glucose monitoring system (SGMS) for long-term glucose monitoring, we investigated the in vivo performance of the system. METHOD The SGMS consists of an implantable ocular mini implant (OMI) and a handheld fluorescence photometer. A clinical study was performed on 47 diabetes patients split into two cohorts. Two d...
متن کاملOlfactory disorders: Diagnosis, evaluation, and treatment
The sense of smell, one of the five basic senses that humans have, helps us detect different types of odors. It also plays an important role in the detection of pollutants, toxic gases, or rotten and hazardous foods. Although olfaction is considered less important than the other senses, smell disorders could cause a variety of problems, including reduced taste detection due to the relationship ...
متن کاملDesign and fabrication of non-invasive blood glucose sensor using pulse width modulation (PWM) technique and analysis of first harmonic amplitude of near infrared spectroscopy
This article has no abstract.
متن کاملکشیدن مولر اول دائمی با پیش آگهی ضعیف در دوران اختلاط دندانی
Whenever the first permanent molar is extracted or its long- term prognosis is poor, before taking any steps, a full clinical and radiographic evaluation associated with patient's dental models investigation is necessary to determine the following cases:The quality and quantity of dentition, teeth missing, occlusion, buds position, orthodontic problems, the level of parents and patient cooperat...
متن کاملPlatelet Factor 3 Based-clotting Time Assay as a Quality Marker for Long-term Storage of Platelet Concentrates
Background: Platelets rapidly lose their qualities usually after 5 day of storage. Different standard methods have been recommended to check the quality of platelets during storage which some of them show better correlation with other quality markers during storage. The purpose of this study was to demonstrate if platelet factor 3 (PF3) assay could be an indicator of storage lesion and provide ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2012