Identification of clinical Streptococcus pneumoniae isolates among other alpha and nonhemolytic streptococci by use of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system.

نویسندگان

  • Damien Dubois
  • Christine Segonds
  • Marie-Françoise Prere
  • Nicole Marty
  • Eric Oswald
چکیده

Discrimination between Streptococcus pneumoniae and its close relatives of the viridans group is a common difficulty in matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry-based identification. In the present study, the performances of the Vitek MS MALDI-TOF mass spectrometry system were assessed using 334 pneumococci, 166 other S. mitis group streptococci, 184 non-S. mitis group streptococci, and 19 related alpha- and nonhemolytic aerobic Gram-positive catalase-negative coccal isolates. Pneumococci had been identified by means of optochin susceptibility and bile solubility or serotyping, and other isolates mainly by use of RapidID32 Strep strips. In case of discordant or low-discrimination results, genotypic methods were used. The sensitivity of the Vitek MS for the identification of S. pneumoniae was 99.1%, since only three bile-insoluble isolates were misidentified as Streptococcus mitis/Streptococcus oralis. Conversely, two optochin-resistant pneumococci were correctly identified (specificity, 100%). Three Streptococcus pseudopneumoniae isolates were also correctly identified. Among nonpneumococcal isolates, 90.8% (n = 335) were correctly identified to the species or subspecies level and 2.4% (n = 9) at the group level. For the remaining 25 isolates, the Vitek MS proposed a bacterial species included in the list of possible species suggested by genotypic methods, except for 4 isolates which were not identified due to the absence of the species in the database. According to our study, the Vitek MS displays performance similar to that of the optochin susceptibility test for routine identification of pneumococcal isolates. Moreover, the Vitek MS is efficient for the identification of other viridans group streptococci and related isolates, provided that the species are included in the database.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of viridans streptococci With Matrix-Assisted Laser Desorption & Ionization Time-of-flight Mass Spectrometry by an In-house Method and a Commercially Available System

Two matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS)-based methods were compared for their ability to identify viridans streptococci. One approach employed a reference database and software developed in-house. All inhouse measurements were performed using an Autoflex II Instrument (Bruker Daltonics GmbH, Germany). The other system, a VITEK-MS (BioMérie...

متن کامل

Multicenter evaluation of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of Gram-positive aerobic bacteria.

Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 sy...

متن کامل

Performance of the Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.

We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS cor...

متن کامل

Identification of clinical Streptococcus pneumoniae isolates among 1 other alpha and nonhemolytic streptococci using the VITEK MS 2 MALDI - TOF mass spectrometry system 3 4

4 Damien DUBOIS, Christine SEGONDS, Marie-Françoise PRERE, Nicole 5 MARTY, Eric OSWALD 6 7 Laboratoire de Bactériologie-Hygiène, Institut Fédératif de Biologie, Centre Hospitalo8 Universitaire, Toulouse, F-31059, France 9 Université Paul Sabatier-Toulouse III, Toulouse, F-31076, France 10 11 Running title: S. pneumoniae identification with MALDI-TOF VITEK MS 12 13 * Corresponding author. 14 Mai...

متن کامل

Using Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Complemented with Selected 16S rRNA and gyrB Genes Sequencing to Practically Identify Clinical Important Viridans Group Streptococci (VGS)

There are challenges in viridans group streptococci (VGS) identification especially for the mitis group. Few studies have investigated the performance of MALDI-TOF MS system in VGS identification. Using 16S rRNA gene and gyrB gene sequencing as a gold standard, the performance of two MALDI-TOF MS instruments in the identification of 181 VGS clinical isolates was studied. The Bruker Biotyper and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 51 6  شماره 

صفحات  -

تاریخ انتشار 2013