Calculation of Correction Factors for Dosimeters Thermoluminescent of Lithium Fluoride (LiF-100) for Use in 6MV Photon Beams
نویسنده
چکیده
Since the beginning of its use, radiation has already presented harm, justifying the necessity of controlled use. In order to monitor its effects and even avoid them, dosimetry has arisen. For the purpose of ensured all the necessary safety and monitor areas where there is radiation use, a lot of devices able to identify and quantify many types of radiation were developed. However, some these dosimeters are more widely used today like ionizing chamber, chemical dosimeters, photographic dosimeters and thermoluminescent dosimeters (TLD). When a group of TLD is obtained with a quantity n of dosimeters, there is a variation of answer of these dosimeters when they are subjected to the same irradiations conditions, from this comes the importance of individual calibration of these, to select the dosimeters with close answers, reducing the uncertainties of the measures. Therefore, this work presents the calculation of correction factors for the TLD of lithium fluoride (LiF-100) and shows how this factors can improve the TLD’s readings. Keywords— dosimetry, TLD, correction factor.
منابع مشابه
Dosimetric study of thermoluminescent detectors in clinical photon beams using liquid water and PMMA phantoms.
The purpose of this study was the dosimetric evaluation of thermoluminescent detectors of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by IPEN compared to the TL response of lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti) dosimeters and microdosimeters produced by Harshaw Chemical Company to clinical photon beams dosimetry (6 and 15 MV) using liquid water and PMMA p...
متن کاملSmall photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملتولید دزیمتر LiF: Mg, Ti و مقایسه پاسخ آن با دزیمتر (LiF: Mg, Ti (TLD-100 ساخت شرکت هارشا در برابر پرتوهای گاما
Thermoluminescence dosimeters are small tablets used with 3. 2*3. 2*0. 9mm^3 for measurement of received dose from radioactive various beams. The most common dosimeter is TLD-100 which is lithium-fluoride family and this dosimeter contain magnesium impurities. In this study, first lithium-flouride powder was mixed with titanium and controlled atmosphere samples were heated. After measuring ...
متن کاملDesign of homogeneous and heterogeneous human equivalent thorax phantom for tissue inhomogeneity dose correction using TLD and TPS measurements
Background: The purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the Treatment Planning Systems (TPS) calculated values for different lung treatment dosimetery. It is compared with Thermoluminescent Dosimeter (TLD) measurement. Materials and Methods: Homogeneous and heterogeneous tho...
متن کاملQuantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam
Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...