Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles.

نویسندگان

  • Neil Greenberg
  • William L Roberts
  • Lorin M Bachmann
  • Elizabeth C Wright
  • R Neil Dalton
  • Jack J Zakowski
  • W Greg Miller
چکیده

BACKGROUND Standardized calibration does not change a creatinine measurement procedure's susceptibility to potentially interfering substances. METHODS We obtained individual residual serum or plasma samples (n = 365) from patients with 19 different disease categories associated with potentially interfering substances and from healthy controls. Additional sera at 0.9 mg/dL (80 μmol/L) and 3.8 mg/dL (336 μmol/L) creatinine were supplemented with acetoacetate, acetone, ascorbate, and pyruvate. We measured samples by 4 enzymatic and 3 Jaffe commercially available procedures and by a liquid chromatography/isotope dilution/mass spectrometry measurement procedure against which biases were determined. RESULTS The number of instances when 3 or more results in a disease category had biases greater than the limits of acceptability was 28 of 57 (49%) for Jaffe and 14 of 76 (18%) for enzymatic procedures. For the aggregate group of 59 diabetes samples with increased β-hydroxybutyrate, glucose, or glycosylated hemoglobin (Hb A(1c)), the enzymatic procedures had 10 biased results of 236 (4.2%) compared with 89 of 177 (50.3%) for the Jaffe procedures, and these interferences were highly procedure dependent. For supplemented sera, interferences were observed in 11 of 24 (46%) of groups for Jaffe and 8 of 32 (25%) of groups for enzymatic procedures and were different at low or high creatinine concentrations. CONCLUSIONS There were differences in both magnitude and direction of bias among measurement procedures, whether enzymatic or Jaffe. The influence of interfering substances was less frequent with the enzymatic procedures, but no procedure was unaffected. The details of implementation of a method principle influenced its susceptibility to potential interfering substances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Risk Assessment of the Jaffe vs Enzymatic Method for Creatinine Measurement in an Outpatient Population

BACKGROUND The Jaffe and enzymatic methods are the two most common methods for measuring serum creatinine. The Jaffe method is less expensive than the enzymatic method but is also more susceptible to interferences. Interferences can lead to misdiagnosis but interferences may vary by patient population. The overall risk associated with the Jaffe method depends on the probability of misclassifica...

متن کامل

Enzymatic creatinine assays allow estimation of glomerular filtration rate in stages 1 and 2 chronic kidney disease using CKD-EPI equation.

The National Kidney Disease Education Program group demonstrated that MDRD equation is sensitive to creatinine measurement error, particularly at higher glomerular filtration rates. Thus, MDRD-based eGFR above 60 mL/min/1.73 m² should not be reported numerically. However, little is known about the impact of analytical error on CKD-EPI-based estimates. This study aimed at assessing the impact of...

متن کامل

Prime time for enzymatic creatinine methods in pediatrics.

BACKGROUND The literature regarding the nonspecificity of applications of the Jaffe (alkaline picrate) reaction for creatinine is generally outdated. We conducted a specificity study to update the nonspecificity information for current Jaffe and enzymatic creatinine assays. METHODS Two serum pools with creatinine concentrations within the pediatric reference interval were spiked with albumin,...

متن کامل

Creatinine determination according to Jaffe—what does it stand for?

In 1886, Max Jaffe discovered a reaction of creatinine with picric acid in an alkaline environment. Although the manuscript describes the nature of a precipitate and does not deal with an analytical assay, Jaffe's landmark paper elucidated the basic principles of the creatinine determination method (originally developed by Otto Folin), which became immensely popular and has easily withstood the...

متن کامل

Enzymatic assays for creatinine: time for action.

Estimation of glomerular filtration rate (eGFR) on the basis of serum creatinine concentration measurements using equations is critical to ongoing global public health efforts to improve the diagnosis and treatment of chronic kidney disease. There is now ongoing activity to promote world-wide standardization of methods to measure creatinine concentrations, together with the introduction of a re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 2012