Feasibility of Ultra-Thin Fiber-Optic Dosimeters for Radiotherapy Dosimetry

نویسندگان

  • Bongsoo Lee
  • Guwon Kwon
  • Sang Hun Shin
  • Jae Seok Kim
  • Wook Jae Yoo
  • Young Hoon Ji
  • Kyoung Won Jang
چکیده

In this study, prototype ultra-thin fiber-optic dosimeters were fabricated using organic scintillators, wavelength shifting fibers, and plastic optical fibers. The sensor probes of the ultra-thin fiber-optic dosimeters consisted of very thin organic scintillators with thicknesses of 100, 150 and 200 μm. These types of sensors cannot only be used to measure skin or surface doses but also provide depth dose measurements with high spatial resolution. With the ultra-thin fiber-optic dosimeters, surface doses for gamma rays generated from a Co-60 therapy machine were measured. Additionally, percentage depth doses in the build-up regions were obtained by using the ultra-thin fiber-optic dosimeters, and the results were compared with those of external beam therapy films and a conventional fiber-optic dosimeter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Scintillating Fiber-optic Dosimeter for Co-60 Radiotherapy

In this study, we have fabricated a scintillating fiberoptic dosimeter (SFOD) for a Co-60 radiotherapy dosimetry. The γrays generated from a Co-60 machine are measured using a SFOD and percent depth dose (PDD) curves are obtained according to the different depths of water phantom. Also, Cerenkov lights generated by the interactions of primary or secondary electrons and a plastic optical fiber a...

متن کامل

Investigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic

Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...

متن کامل

Uncertainty in 3D gel dosimetry

Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hin...

متن کامل

Evaluation of PMMA optical fibres as gamma dosimeters for nuclear applications

Fibre optic radiation monitors have promising applications in the nuclear industry. We investigate the possible use of PMMA plastic optical fibres as on-line dosimeters, based on the measurement of the attenuation induced by the ionising gamma radiation. A novel interrogation scheme is proposed for real-time dosimetry applications. This technique involves using spectral measurement techniques w...

متن کامل

In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy.

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015