Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T1 mapping using a cine steady-state look-locker approach.
نویسندگان
چکیده
PURPOSE To develop and evaluate a cardiac phase-resolved myocardial T1 mapping sequence. METHODS The proposed method for temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ) is based on contiguous fast low-angle shot imaging readout after magnetization inversion from the pulsed steady state. Thereby, segmented k-space data are acquired over multiple heartbeats, before reaching steady state. This results in sampling of the inversion-recovery curve for each heart phase at multiple points separated by an R-R interval. Joint T1 and B1+ estimation is performed for reconstruction of cardiac phase-resolved T1 and B1+ maps. Sequence parameters are optimized using numerical simulations. Phantom and in vivo imaging are performed to compare the proposed sequence to a spin-echo reference and saturation pulse prepared heart rate-independent inversion-recovery (SAPPHIRE) T1 mapping sequence in terms of accuracy and precision. RESULTS In phantom, TOPAZ T1 values with integrated B1+ correction are in good agreement with spin-echo T1 values (normalized root mean square error = 4.2%) and consistent across the cardiac cycle (coefficient of variation = 1.4 ± 0.78%) and different heart rates (coefficient of variation = 1.2 ± 1.9%). In vivo imaging shows no significant difference in TOPAZ T1 times between the cardiac phases (analysis of variance: P = 0.14, coefficient of variation = 3.2 ± 0.8%), but underestimation compared with SAPPHIRE (T1 time ± precision: 1431 ± 56 ms versus 1569 ± 65 ms). In vivo precision is comparable to SAPPHIRE T1 mapping until middiastole (P > 0.07), but deteriorates in the later phases. CONCLUSIONS The proposed sequence allows cardiac phase-resolved T1 mapping with integrated B1+ assessment at a temporal resolution of 40 ms. Magn Reson Med 79:2087-2100, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
منابع مشابه
Assessment of diffuse myocardial fibrosis in rats using small-animal Look-Locker inversion recovery T1 mapping.
BACKGROUND The concentration of gadopentetate dimeglumine in myocardium and blood can be assessed from T1 measurements and can be used to calculate the extracellular volume (ECV) of the myocardium. We hypothesized that diffuse myocardial fibrosis in a small-animal model could be quantitatively assessed by measuring myocardial ECV using small-animal Look-Locker inversion recovery T1 mapping. M...
متن کاملValidation of Small-Animal Look-Locker Inversion Recovery (SALLI) Cine versus Cine MR in assessment of left ventricular function
Background Small-Animal Look-Locker Inversion Recovery (SALLI) is a novel imaging method that generates simultaneously cardiac T1 maps, cine MR and inversion recovery-prepared images for high heart rates. T1 mapping by SALLI has been tested and compared with histology, however the assessment of left ventricular (LV) function has not yet been validated. Our aim was to compare the measurement of ...
متن کاملMyocardial T1 mapping at 3.0T using inversion recovery FLASH readout
Background Myocardial T1 mapping methods such as modified Look-Locker inversion-recovery (MOLLI) typically use balanced steady state free precession (bSSFP) readout, which is known to be particularly sensitive to off resonance and thus limits its utility at higher field strengths. Fast low angle shot (FLASH) imaging is known to be more robust against susceptibility artifacts than bSSFP. However...
متن کاملAssessment of cardiac function and myocardial morphology using small animal Look-Locker inversion recovery (SALLI) MRI in rats.
Small animal magnetic resonance imaging is an important tool to study cardiac function and changes in myocardial tissue. The high heart rates of small animals (200 to 600 beats/min) have previously limited the role of CMR imaging. Small animal Look-Locker inversion recovery (SALLI) is a T1 mapping sequence for small animals to overcome this problem. T1 maps provide quantitative information abou...
متن کاملFast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state: optimization for accuracy and reliability.
A fast T(1) measurement sequence using inversion recovery Look-Locker echo-planar imaging at steady state (IR LL-EPI SS) is presented. Delay time for a full magnetization recovery is not required in the sequence, saving acquisition time significantly for high-resolution T(1) mapping. Imaging parameters of the IR LL-EPI SS sequence were optimized to minimize the bias from the excitation pulses i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 79 4 شماره
صفحات -
تاریخ انتشار 2018