Energy Renovation of Buildings Utilizing the U-value Meter, a New Heat Loss Measuring Device
نویسنده
چکیده
A new device with the ability to measure heat loss from building facades is proposed. Yet to be commercially developed, the U-value Meter can be used as stand-alone apparatus, or in combination with thermographic-equipment. The U-value meter complements thermographs, which only reproduce surface temperature and not the heat loss distribution. There is need for a device that measures the heat loss in a quantitative manner. Convective as well as radiative heat losses are captured and measured with a five-layer thermal system. Heat losses are measured in the SI-unit W/m 2 K. The aim is to achieve more cost-effective building renovation, and provide a means to check the fulfillment of Building Regulation requirements with respect to stated U-values (heat transmission coefficients). In this way it should be possible to greatly reduce energy consumption of buildings.
منابع مشابه
Autonomous Wireless Heat Energy Meter based on Piezoelectric Energy Harvester for Heat Energy Measurement in Building Complexes
This paper presents a platform for power autonomous wireless energy meter device using piezoelectric energy harvesters. This device can be mainly used for measuring the share of heat energy consumption in a fair manner in building complex with central heat energy system. In the suggested device, the piezoelectric energy harvester is also used as a flow-meter to reduce the power consumption of t...
متن کاملComparison of heat loss and air infiltration through the openings of Qajar and Pahlavi era houses in Tabriz
The rapidly growing world energy use has already raised concerns over energy resources and greenhouse gas (GHG) emissions. Since the global contribution from residential buildings towards energy consumption, has steadily increased between 20% and 40% and as large openings have considerable energy and heat loss in dwellings, this paper establishes a coefficient of heat loss and air infiltration ...
متن کاملA New Suburb Renovation Concept
Finnish national research project, Userand Businessoriented Suburb Renovation Concept (KLIKK), was started in January 2012 and will end in June 2014. The perspective of energy efficiency is emphasised in the project, but also it addresses what improving the energy efficiency of suburban apartment buildings means from the standpoint of architecturally valuable buildings representing different pe...
متن کاملEnergy Performance Indicators in the Swedish Building Procurement Process
In Sweden, all new buildings need to comply with the National Board of Housing, Building and Planning’s requirement on specific purchased energy (kWh/m2). Accordingly, this indicator is often used to set design criteria in the building procurement process. However, when energy use is measured in finished buildings, the measurements often deviate significantly from the design calculations. The m...
متن کاملAnalysis of the Performance of Vacuum Glazing in Office Buildings in Korea: Simulation and Experimental Studies
Window performance in buildings is very important for energy saving. Many efforts have been made towards saving energy in buildings, and research has focused attention on enhancing the thermal performance of windows. Vacuum glazing has attracted much interest as a means of enhancing the thermal performance of windows by strengthening insulation performance. However, the performance of vacuum gl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -