Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

نویسنده

  • Don Potter
چکیده

Many routine laboratories have adopted ICP-MS as their primary technique for metals analysis due to its simple operation as a multi-element analyzer. However, despite its higher performance for the targeted removal of specific interferences, collision/reaction cell (CRC) ICP-MS remains relatively understudied in terms of its multielement capability. This work demonstrates that the Agilent 7500ce ICP-MS can be operated with a single set of He cell gas conditions, to provide effective interference removal for a range of elements in a challenging and complex sample matrix.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS Application

The new Agilent 7500cx with Octopole Reaction System (ORS) is capable of analyzing most typical environmental samples using only one mode of analysis: helium mode. For the first time, it is possible to analyze an entire environmental suite of elements, including Hg and the major elements such as Na, K, Ca, Mg, Al, and Fe, in less than 2.5 minutes per sample, under conditions that remove or redu...

متن کامل

Basic Performance of the Agilent 7700s ICP-MS for the Analysis of Semiconductor Samples

Agilent ICP-MS systems have become the benchmark for accurate low-level analysis of trace contaminants across a wide range of high-purity chemicals used in the semiconductor industry. As the first commercial ICP-MS to offer reliable and routine cool plasma operation, the Agilent 4500 Series ICP-MS set the standard for low level analysis of the previously problematic elements Na, K, Ca and Fe. B...

متن کامل

Determination of iopromide in environmental waters by ion chromatography - ICP - MS

The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of ioprom...

متن کامل

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Rapid semiquantitative elemental screening of pharmaceutical samples is described using the Agilent 7500ce ICP-MS with helium as collision gas. Polyatomic interferences are eliminated in the He pressurized cell, enabling rapid elemental profiling of pharmaceutical tablets for screening purposes. Elements which normally suffer from polyatomic interferences have been included in the semiquantitat...

متن کامل

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Inductively coupled plasma mass spectrometry (ICP-MS) is a key analytical tool in many laboratories. It is used for elemental determinations across a wide range of analyses, including environmental, semiconductor, food safety, geological, chemical, petrochemical, nuclear, clinical, forensic, and research applications. Since the early publications during the development of ICP-MS, it has been ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006