The dynamic locking blade plate, a new implant for intracapsular hip fractures: biomechanical comparison with the sliding hip screw and Twin Hook.

نویسندگان

  • W H Roerdink
  • A M M Aalsma
  • G Nijenbanning
  • A D P van Walsum
چکیده

Internal fixation of intracapsular hip fractures results in a high failure rate with non-union and avascular necrosis being the two most important complications. In order to prevent these possible complications treatment should consist of an anatomical reduction and stable fixation by insertion of a low volume, dynamic implant, providing angular and rotational stability to the femoral head. According to these principles a new implant, the dynamic locking blade plate (DLBP) was designed for the fixation of intracapsular hip fractures. We performed a biomechanical analysis in synthetic bone to compare the rotational stability and cut out resistance of the DLBP with a conventional sliding hip screw (SHS) and the more recently developed Twin Hook. The rotational stability of the DLBP proved to be three times higher than the rotational stability of a SHS and two times higher than the Twin Hook. There was no major difference in cut out resistance between the different implants. The design of the DLBP and possible advantages with regard to the healing of an intracapsular hip fracture are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures – postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate

BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...

متن کامل

Twin hook fixation for proximal femoral fractures.

PURPOSE To report results of twin hook fixation for proximal femoral fractures in comparison to those fixed with the conventional lag screw. METHODS Between August 2005 and July 2006, 2 men and 15 women aged 74 to 94 (mean, 85) years with proximal femoral fractures underwent open reduction and internal fixation using the twin hook system. The tip-apex distance was compared with that in 20 pat...

متن کامل

Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation.

OBJECTIVE To compare the fixation stability in the femoral head with sliding hip screw versus helical blade designs for unstable, intertrochanteric hip fractures. METHODS A simulated, unstable intertrochanteric hip fracture was created in six pairs of cadaveric femurs. One of each pair was treated using an intramedullary nail with a sliding hip screw (ITST) for femoral head fixation and the o...

متن کامل

Intra-Pelvic Migration of Sliding Hip Screw During Osteosynthesis of Hip Fracture: A Rare Avoidable Intraoperative Complication

INTRODUCTION Hip fractures, which are common among old patients, are classified into two groups: intracapsular and extracapsular fractures. Extracapsular fractures can be treated with extramedullary implants [e.g. dynamic hip screw (DHS)] or intramedullary nails. Dynamic hip screw is the treatment of choice in stable pertrochanteric fractures. Intrapelvic migration of the sliding screw is a ver...

متن کامل

Early experience of dynamic hip screw with spiral blade and locking side plate for the stabilization of trochanteric fractures.

OBJECTIVE To evaluate early experience with helical hip system in osteoporotic elderly patients with per-trochanteric fractures. METHODS The retrospective study was conducted at Aga Khan University Hospital, Karachi, and comprised records of patients having low-velocity pertrochanteric fractures who were fixed with spiral blade Dynamic Helical Hip Systemfrom July to December 2014 and were fol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2009