Aneurysm formation at both ends of an endograft associated with maladaptive aortic changes after endovascular aortic repair in a healthy patient.
نویسندگان
چکیده
We report a case in which saccular aneurysms formed at both ends of an endograft that exhibited maladaptive aortic changes after endovascular aortic repair in a patient without significant evidence of connective tissue disease. A 66-year old male underwent thoracic endovascular aortic repair (TEVAR) for a distal aortic arch aneurysm. A follow-up computed tomography (CT) scan performed at 6 months after the TEVAR detected a small saccular aneurysm at the distal edge of the endograft. At 10 months after the TEVAR, a new large aneurysm appeared at the proximal edge of the endograft. To prevent the latter aneurysm rupturing, total arch replacement with endograft fixation was performed. A CT scan obtained at 18 months after the TEVAR demonstrated that the aneurysm at the distal edge of the endograft had progressed and so we considered reintervention. Unfortunately, the patient died of intracranial haemorrhaging before the second procedure could be carried out. A histopathological examination of the aneurysm wall did not detect any significant background factors, such as connective tissue disease, inflammation or infection. The present case involved unexpected late complications, which might have been caused by changes in the form of the aorta after TEVAR.
منابع مشابه
An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملLate lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm
We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.
متن کاملFrequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019
Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR. Materials and methods: In this cross-sectional study, medical records were reviewed...
متن کاملAORTIC TRANSECTION AND ITS SURGICAL REPAIR: A CASE REPORT FROM IRAN
Aortic transection is a rare but life-threatening complication of blunt chest trauma. Treatment options include open repair, medical management and most recently, endovascular repair. We report a 33 years old male with a traumatic aortic transection following a car accident. Aortic injury and its pseudo-aneurysm were confirmed by Chest CT scan and TEE in the descending thoracic aorta just belo...
متن کاملExternalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch
PURPOSE To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2013