Comparison of Design Procedures for Pre Engineering Buildings (PEB): A Case Study
نویسندگان
چکیده
In recent years, the introduction of Pre Engineered Building (PEB) concept in the design of structures has helped in optimizing design. The adoptability of PEB in the place of Conventional Steel Building (CSB) design concept resulted in many advantages, including economy and easier fabrication. In this study, an industrial structure (Ware House) is analyzed and designed according to the Indian standards, IS 800-1984, IS 800-2007 and also by referring MBMA-96 and AISC-89. In this study, a structure with length 187m,width 40m,with clear height 8m and having R-Slope 1:10,isconsidered to carry out analysis& design for 2D frames (End frame, frame without crane and frame with 3 module cranes). The economy of the structure is discussed in terms of its weight comparison, between Indian codes (IS800-1984, IS800-2007) & American code (MBMA-96), & between Indian codes (IS800-1984, IS800-2007). Keywords—AISC, Crane Beam, MBMA, Pre-EngineeredBuildings, Staad Pro, Utilization Ratio.
منابع مشابه
Seismic fragility assessment of RC moment resisting frame buildings designed for different editions of Iranian seismic design code
Background and objective: Developing fragility and vulnerability functions are important tools in seismic reliability assessment of buildings and are widely used in regional seismic risk studies. To date sufficient studies for developing analytical fragility functions for Iranian code-conforming buildings have not been carried out. Performing such studies are necessary to assess the adequacy of...
متن کاملcomparison of pre-cooling and topical anasthetic in pain perception of palatal injection among pediatric patients
Introduction: The Palatal injection is one of the most painful procedures in dentistry which could establish an unpleasant experience for pediatric patients. No study has been carried out to assess the effects of pre-cooling with ice during palatal injection for children yet. The present research is focused on comparison of the efficacy of pre-cooling and topical anesthetic gel on the pain perc...
متن کاملNumerical Study of Progressive Collapse in Intermediate Moment Resisting Reinforced Concrete Frame Due to Column Removal
Progressive collapse is a chain reaction of failures propagating throughout a portion of the structure disproportionate to the original local failure occurring when a sudden loss of a critical load‐bearing element initiates a structural element failure, eventually resulting in partial or full collapse of the structure. Both General Services Administration (GSA) and United States Department of D...
متن کاملSeismic Damage and Disaster Management Maps (A Case Study)
There are many cities in developing countries that are built with minimal seismic considerations. Also, due to the expenses involved regarding detailed and analytical identification of such vulnerable buildings and structures in these cities, is very difficult and also time consuming. It is necessary and much needed to have a quick and inexpensive solution for such assessment in cities with the...
متن کاملArchitectural Design Optimization of School Buildings for Reduction of Energy Demand in Hot & Dry Climates of Iran
School buildings as a major part of public buildings are considered as one of the basic consumers of energy in Iran. Based on building typology and occupancy patterns, school buildings have a great potentiality for energy optimization while providing thermal comfort. This study investigates the architectural design parameters such as orientation, optimum window to wall ratio, space organization...
متن کامل