Should all elective knee radiographs requested by general practitioners be performed weight-bearing?

نویسندگان

  • Alvin Chen
  • Joshua Balogun-Lynch
  • Kavita Aggarwal
  • Elizabeth Dick
  • Chinmay M Gupte
چکیده

The aims of this study were to: [1] Assess the number of patients with suspected knee osteoarthritis that underwent repeat weight-bearing(WB) knee radiographs in the orthopaedic clinic following initial non-WB radiograph requested by their general practitioner (GP). [2] Confirm whether repeating WB knee views changed radiology reports. [3] Determine the number of London trusts with protocols for routinely performing WB views. A Retrospective cohort study of 1968 patients aged >40 years referred to a London teaching hospital for knee radiographs over 12 months. Radiographs were identified as WB/non-WB. Subsequent repeat WB views performed in those that went on to have an orthopaedic consultation were also documented. A consultant musculoskeletal radiologist reported both images. A proforma containing a likert scale of severity for commonly reported abnormalities in knee osteoarthritis and criteria from the Kellgren and Lawrence scale was used for reporting. London NHS Trusts were surveyed to identify if protocols were in place for performing WB views. A total of 1,968 patients underwent knee radiographs, of which 1922 (97.7%) had initial non-WB radiographs. Of the 56 patients in this group that underwent required repeat WB radiographs, joint space narrowing was reported as more severe on WB versus non-WB radiographs (p = 0.035). Only 54% of departments routinely performed WB radiographs. Few patients (2.3%) referred by GPs have WB radiographs requested. Some of those referred for a specialist opinion required repeat WB views. Nearly half of London hospitals do not routinely perform WB radiographs. This represents a significant financial burden to the NHS, increased radiation exposure and wasted patient/clinician time. We propose that all GP requested knee radiographs be performed as WB unless otherwise stated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation☆

OBJECTIVE To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. METHODS An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographi...

متن کامل

Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy

Purpose To compare navigation and weight bearing radiographic measurements of mechanical axis (MA) before and after closed wedge high tibial osteotomy (HTO) and to evaluate post-osteotomy changes in MA assessed during application of external varus or valgus force. Materials and Methods Data from 30 consecutive patients (30 knees) who underwent computer-assisted closed-wedge HTO were prospecti...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment.

BACKGROUND Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. METHODS One hundred eight pati...

متن کامل

Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition

PURPOSE To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. MATERIALS AND METHODS From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014