Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis

نویسندگان

  • Yuhwai Tseng
  • Chauchin Su
  • Yingchieh Ho
  • Xiaosong Hu
چکیده

BACKGROUND Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest. MATERIALS AND METHODS The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal. RESULTS A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB. CONCLUSION The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal-to-noise quality of 10 dB if the high-pass 3 dB frequency is suitably selected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring the Transmission Characteristic of the Human Body in an Electrostatic-Coupling Intra Body Communication System Using a Square Test Stimulus

This study employs a simple measurement methodology that is based on the de-convolution of a square test stimulus to measure the transmission characteristics of the human body channel in an electrostaticcoupling intra body communication system. A battery-powered square waveform generator was developed to mimic the electrostatic-coupling intra body communication system operating in the environme...

متن کامل

Analysis and Design of Wide-Band Digital Transmission in an Electrostatic-Coupling Intra-Body Communication System

This study develops a form of digital baseband Intra-Body communication for wideband transmission. A simplified circuit model of signal and noise is constructed to analyze the contribution of the high pass filter function of the electrostatic coupling Intra-Body communication system to wideband digital transmission in electrostatic coupling Intra-Body communication. A unit step function is pres...

متن کامل

Galvanic coupling intra-body communication channel model based on anisotropic muscular tissue

Background: Characteristics of human tissues have direct effects on transmission property of the current signal in human tissues. It is learned from anatomy that, characteristics of all human tissues are not identical, and some like skin and fat are isotropic, while others like muscle are anisotropic. Muscular tissue has a great effect on transmission and distribution of the current signal in h...

متن کامل

Intra-body communication for biomedical sensor networks

Intra-body communication is a novel data transmission method that uses the human body as an electrical channel. The idea is driven by the vision of a cable-free biomedical monitoring system. On-body and implanted sensors monitor the vital functions and transfer data through the human body to a central monitoring unit. Especially for risk patients and long-term applications, such a technology of...

متن کامل

Effects of human limb gestures on galvanic coupling intra-body communication for advanced healthcare system

BACKGROUND Intra-Body Communication (IBC), which utilizes the human body as the transmission medium to transmit signal, is a potential communication technique for the physiological data transfer among the sensors of remote healthcare monitoring system, in which the doctors are permitted to remotely access the healthcare data without interrupt to the patients' daily activities. METHODS This wo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016