Systematic review of the diagnostic accuracy of 99mTc-HMPAO-SPECT in dementia.

نویسندگان

  • Nadine J Dougall
  • Sjoerd Bruggink
  • Klaus P Ebmeier
چکیده

OBJECTIVE The authors sought to determine the diagnostic accuracy of 99mTc-HMPAO-SPECT in discriminating between Alzheimer disease (AD) and other dementias. METHODS Articles published between 1985 and 2002 were retrieved systematically from MEDLINE and EMBASE, cross-referencing with personal collections and 13 narrative reviews. Of 301 studies identified, 48 survived exclusion criteria and contained extractable data. Two authors independently assessed and graded the methodology of all included studies. Diagnostic comparison groups included vascular dementia (VD; 13 studies), fronto-temporal dementia (FTD; 7 studies), normal healthy volunteers (27 studies), and non-dementia patients (13 studies). Where statistically justified, groups were pooled in a metaanalysis; summary receiver operating curves were constructed; and heterogeneity across studies examined by regression of the diagnostic odds ratio. RESULTS The pooled weighted sensitivity of 99mTc-HMPAO-SPECT in discriminating clinically defined AD from VD was 71.3%; its specificity was 75.9%. The pooled weighted sensitivity and specificity for AD versus FTD were 71.5% and 78.2%, respectively. Variation in outcome across studies was not found to be attributable to any single factor. CONCLUSION Pathological verification studies suggest that clinical criteria may be more sensitive in detecting AD than brain SPECT (81% versus 74%). However, SPECT studies provide a higher specificity against other types of dementia than clinical criteria (91% versus 70%). SPECT may, therefore, be helpful in the differential diagnosis of AD. Clinical follow-up studies are urgently required to establish its predictive validity with regard to natural history and treatment response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

A clinical role for 99mTc-HMPAO SPECT in the investigation of dementia?

OBJECTIVES To provide the clinician with a guide to the clinical utility of 99mTc-HMPAO single photon emission computed tomography (SPECT) and to the interpretation of specific test results in the differential diagnosis of dementia. METHODS Three hundred and sixty three patients with dementia were studied prospectively for a median three (range 1-6) years and classified into disease groups on...

متن کامل

Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis.

OBJECTIVES Most studies that clinically validated peri-ictal SPECT in intractable partial epilepsy had used technetium-99m-hexamethylpropylene amine oxime (99mTc-HMPAO or 99mTc-exametazime) as the radiopharmaceutical. Because of some theoretical advantages, technetium-99m-ethyl cysteinate diethylester (99mTc-ECD or 99mTc-bicisate) is increasingly being used instead. This study compares unstabil...

متن کامل

A pictorial essay on brain perfusion SPECT in various neuro-psychiatric disorders and intoxication: Though practical, it is not very commonly used

Brain single-photon emission computerized tomography (SPECT), in particular, with perfusion agents or with neuroreceptor imaging radiopharmaceuticals, is rapidly becoming a clinical tool in many neurologic and psychiatric conditions. This imaging modality has been used for diagnosis, prognosis assessment, evaluation of response to therapy, risk stratification, detection of benign vs. malignant ...

متن کامل

Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of geriatric psychiatry : official journal of the American Association for Geriatric Psychiatry

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2004