Plane-parallel ionization chamber for X-radiation of conventional radiography and mammography* Câmara de ionização de placas paralelas para radiação-X de radiografia convencional e mamografia
نویسندگان
چکیده
OBJECTIVE: To develop a double-faced plane-parallel ionization chamber for measurement of air kerma and air kerma rate in X-radiation fields utilized in conventional radiography and mammography. MATERIALS AND METHODS: The chamber has entrance windows made of aluminized polyester film, inner and guard electrodes of aluminum at one side (face A) and graphite at the other side (face G). The present study evaluated operational characteristics as regards response linearity, angular and energy dependence. RESULTS: The linearity of response was 0.86% for face A and 0.92% for face G. For radiation incidence angles, of 0° to ± 5°, the response variation was less than 0.8% for both faces of the chamber. The energy dependence of response was 0.8% for face A on X-ray qualities for conventional radiography, and 2.4% for the face G of the chamber on X-ray qualities for mammography. CONCLUSION: This chamber can be utilized on a routine basis for measurement of air kerma and air kerma rate in X-ray beams utilized in conventional radiography and mammography.
منابع مشابه
An Efficiency Studying of an Ion Chamber Simulation Using Vriance Reduction Techniques with EGSnrc
Background: Radiotherapy is an important technique of cancer treatment using ionizing radiation. The determination of total dose in reference conditions is an important contribution to uncertainty that could achieve 2%. The source of this uncertainty comes from cavity theory that relates the in-air cavity dose and the dose to water. These correction factors are determined from Monte Carlo calcu...
متن کاملReproducibility of pixel values for two photostimulable phosphor plates in consecutive standardized scannings Reprodutibilidade dos valores de “pixels” de duas placas de fósforo fotoestimuláveis em leituras padronizadas consecutivas
The objective of the present study was to determine the reproducibility of the pixel values obtained with the Digora system (Soredex, Finland). Exposures were standardized, with variation in exposure and scanning time of two photostimulable phosphor plates containing a stepwedge image. The smallest variation in pixel values ranged from 50 to 75%, with the widest variations being observed in les...
متن کاملEarly detection of breast cancer in Brazil: data from the National Health Survey, 2013
OBJECTIVE To analyze whether the actions of early detection of breast cancer, initiated with the medical request for mammography, differ between users of the Brazilian Unified Health System (SUS) and those who have private health insurance. METHODS From the data collected in the National Health Survey, we estimated the proportions of women who had medical request for mammography according to ...
متن کاملApplication of a tandem ionization chamber in a quality control program of X-ray beams, radiotherapy level
A tandem ionization chamber, developed at the Instituto de Pesquisas Energéticas e Nucleares (IPEN), for X radiation beams, radiotherapy level, was applied into a quality control program of the Calibration Laboratory of IPEN. This ionization chamber is composed by two ionization chambers, with a volume of 0.6 cm each one. Its inner plane-parallel electrodes and guard rings are made of different...
متن کاملComparative study between conventional and digital radiography in cephalometric analysis Estudo comparativo entre radiografia convencional e digital na análise cefalométrica
Objective – Technological improvement is usually followed by comparisons between conventional and new. Those who work with radiographic assessment, such as cephalometric analysis for orthodontic diagnosis, have been living a new challenging and learning phase since the introduction of digital images. It is possible to obtain reproducible and clear images with digital radiography, but radiograph...
متن کامل