RATIONALE A miniature time-of-flight mass spectrometer measuring 20 cm in length has been adapted to demonstrate two-step laser desorption/ionization (LDI) in a compact instrument package for enhanced organics detection. Two-step LDI decouples the desorption and ionization processes, relative to traditional LDI, in order to produce low-fragmentation mass spectra of organic analytes. Tuning the UV ionization laser energy would allow control of the degree of fragmentation, which might enable better identification of constituent species. METHODS A reflectron time-of-flight mass spectrometer prototype was modified to allow a two-laser configuration, with IR (1064 nm) desorption followed by UV (266 nm) postionization. A relatively low ion extraction voltage of 5 kV was applied at the sample inlet. RESULTS The instrument capabilities and performance were demonstrated with analysis of a model polycyclic aromatic hydrocarbon, representing a class of compounds important to the fields of Earth and planetary science. Two-step laser mass spectrometry (L2MS) analysis of a model PAH, pyrene, was demonstrated, including molecular ion identification and the onset of tunable fragmentation as a function of ionizing laser energy. Mass resolution m/Δm = 380 at full width at half-maximum was achieved for gas-phase postionization of desorbed neutrals in this highly compact mass analyzer. CONCLUSIONS Achieving L2MS in a highly miniaturized instrument enables a powerful approach to the detection and characterization of aromatic organics in remote terrestrial and planetary applications. Tunable detection of molecular and fragment ions with high mass resolution, diagnostic of molecular structure, is possible on such a compact L2MS instrument. The selectivity of L2MS against low-mass inorganic salt interferences is a key advantage when working with unprocessed, natural samples, and a mechanism for the observed selectivity is proposed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

A Miniature AOTF-LDTOF Spectrometer Suite for the Detection of Biomarkers on Planetary Surfaces

Biomarkers on Planetary Surfaces. Kyle Uckert, Nancy J. Chanover, David A. Glenar, David G. Voelz, Xifeng Xiao, Rula Tawalbeh, Penelope Boston, William Brinckerhoff, Stephanie Getty, and Paul Mahaffy, New Mexico State University, Las Cruces, NM, USA ([email protected]), New Mexico Institute of Mining and Technology, Socorro, NM USA, and NASA’s Goddard Space Flight Center We discuss the developme...

متن کامل

Laser time-of-flight mass spectrometry for space

We describe a miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis. The laser ablation mass spectrometer ~LAMS! measures the elemental and isotopic composition of regolith materials without any sample preparation or high-voltage source extraction. The small size (,2310 cm) and low mass ~;2 kg! of LAMS, due to its fully coaxial design and two-stage reflect...

متن کامل

Miniaturized time-resolved Raman spectrometer for planetary science based on a fast single photon avalanche diode detector array.

We present recent developments in time-resolved Raman spectroscopy instrumentation and measurement techniques for in situ planetary surface exploration, leading to improved performance and identification of minerals and organics. The time-resolved Raman spectrometer uses a 532 nm pulsed microchip laser source synchronized with a single photon avalanche diode array to achieve sub-nanosecond time...

متن کامل

Dustbuster: a compact impact-ionization time-of-flight mass spectrometer for in situ analysis of cosmic dust

We report on the design and testing of a compact impact-ionization time-of-flight mass spectrometer for analysis of cosmic dust, suitable for use on deep space missions. The instrument, Dustbuster, incorporates a large target area with a reflectron, simultaneously optimizing mass resolution, particle detection, and ion collection. Dust particles hit the 65-cm target plate and are partially ioni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 26 23  شماره 

صفحات  -

تاریخ انتشار 2012