Number of Days Required to Estimate Habitual Activity Using Wrist-Worn GENEActiv Accelerometer: A Cross-Sectional Study

نویسندگان

  • Christina B. Dillon
  • Anthony P. Fitzgerald
  • Patricia M. Kearney
  • Ivan J. Perry
  • Kirsten L. Rennie
  • Robert Kozarski
  • Catherine M. Phillips
چکیده

INTRODUCTION Objective methods like accelerometers are feasible for large studies and may quantify variability in day-to-day physical activity better than self-report. The variability between days suggests that day of the week cannot be ignored in the design and analysis of physical activity studies. The purpose of this paper is to investigate the optimal number of days needed to obtain reliable estimates of weekly habitual physical activity using the wrist-worn GENEActiv accelerometer. METHODS Data are from a subsample of the Mitchelstown cohort; 475 (44.6% males; mean aged 59.6±5.5 years) middle-aged Irish adults. Participants wore the wrist GENEActiv accelerometer for 7-consecutive days. Data were collected at 100Hz and summarised into a signal magnitude vector using 60s epochs. Each time interval was categorised according to intensity based on validated cut-offs. Spearman pairwise correlations determined the association between days of the week. Repeated measures ANOVA examined differences in average minutes across days. Intraclass correlations examined the proportion of variability between days, and Spearman-Brown formula estimated intra-class reliability coefficient associated with combinations of 1-7 days. RESULTS Three hundred and ninety-seven adults (59.7±5.5yrs) had valid accelerometer data. Overall, men were most sedentary on weekends while women spent more time in sedentary behaviour on Sunday through Tuesday. Post hoc analysis found sedentary behaviour and light activity levels on Sunday to differ to all other days in the week. Analysis revealed greater than 1 day monitoring is necessary to achieve acceptable reliability. Monitoring frame duration for reliable estimates varied across intensity categories, (sedentary (3 days), light (2 days), moderate (2 days) and vigorous activity (6 days) and MVPA (2 days)). CONCLUSION These findings provide knowledge into the behavioural variability in weekly activity patterns of middle-aged adults. Since Sunday differed from all other days in the week this suggests that day of the week cannot be overlooked in the design and analysis of physical activity studies and thus should be included in the study monitoring frames. Collectively our data suggest that six days monitoring, inclusive of Saturday and Sunday, are needed to reliably capture weekly habitual activity in all activity intensities using the wrist-worn GENEActiv accelerometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerometer wear-site detection: When one site does not suit all, all of the time.

OBJECTIVES Choice of accelerometer wear-site may facilitate greater compliance in research studies. We aimed to test whether a simple method could automatically discriminate whether an accelerometer was worn on the hip or wrist from free-living data. DESIGN Cross-sectional. METHODS Twenty-two 10-12y old children wore a GENEActiv at the wrist and at the hip for 7-days. The angle between the ...

متن کامل

Influence of Accelerometer Type and Placement on Physical Activity Energy Expenditure Prediction in Manual Wheelchair Users

PURPOSE To assess the validity of two accelerometer devices, at two different anatomical locations, for the prediction of physical activity energy expenditure (PAEE) in manual wheelchair users (MWUs). METHODS Seventeen MWUs (36 ± 10 yrs, 72 ± 11 kg) completed ten activities; resting, folding clothes, propulsion on a 1% gradient (3,4,5,6 and 7 km·hr-1) and propulsion at 4km·hr-1 (with an addit...

متن کامل

Estimation of Daily Energy Expenditure in Pregnant and Non-Pregnant Women Using a Wrist-Worn Tri-Axial Accelerometer

BACKGROUND Few studies have compared the validity of objective measures of physical activity energy expenditure (PAEE) in pregnant and non-pregnant women. PAEE is commonly estimated with accelerometers attached to the hip or waist, but little is known about the validity and participant acceptability of wrist attachment. The objectives of the current study were to assess the validity of a simple...

متن کامل

Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity

BACKGROUND Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. METHODS Twe...

متن کامل

Healthy obesity and objective physical activity123

Background: Disease risk is lower in metabolically healthy obese adults than in their unhealthy obese counterparts. Studies considering physical activity as a modifiable determinant of healthy obesity have relied on self-reported measures, which are prone to inaccuracies and do not capture all movements that contribute to health. Objective: We aimed to examine differences in total and moderatet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016