Effect of alloy type and casting technique on the fracture strength of implant-cemented structures.

نویسندگان

  • Raquel Castillo-de Oyagüe
  • Raquel Osorio
  • Christopher Lynch
  • Alan Gilmour
  • Manuel Toledano
چکیده

OBJECTIVES To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. STUDY DESIGN Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR, Microtest) until fracture. Axial compressive loads were applied at the central fossa of the pontics. FS data were recorded and surface topography of the fractured connectors was SEM-analyzed. A Chi-Square test was performed to assess the dependence of pores on the alloy type and casting procedure. ANOVA and Student-Newman-Keuls (SNK) tests were run for FS comparisons (p <0.05). RESULTS One third of the C structures showed pores inside the fractured connectors. T frameworks demonstrated higher FS than that of C specimens exhibiting pores (p=0.025). C samples containing no pores recorded the greatest mean FS (p <0.001). CONCLUSIONS Fracture strength of metallic frameworks depended on the alloy type and casting procedure. Cobalt-chromium casts often registered pores inside the connectors, which strongly decreased the fracture resistance. An accurate casting of titanium with a pressure-differential system may result in the most predictable technique under the tested experimental conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FORMATION OF GLOBULAR STRUCTURES IN ALUMINUM A356 ALLOY BY NARROWMELT STREAM (NMS) TECHNIQUE

Abstract: structures in alloys. This method is based on pouring the melt through a small sized nozzle into a mould located at acertain height under the crucible. This simple method generates globular structures without using equipments such asimpellers, electromagnetic stirrers, ultrasonic probes and cooling slopes. Therefore it is cost effective. In the presentstudy, the effect of casting size...

متن کامل

Investigation on effect of holding time in brazing of steel to cemented carbide using Cu-Ag alloy filler metal

Nowadays, cemented carbides-steels joints by brazing method are taken into consideration. One of the problems of these joints is the creation residual stresses that can reduce it with choose correct parameters of brazing. In this study, Silver base alloy filler containing copper, zinc and cadmium have been used in temperature 780°C and the effect of time parameter 5, 10 and 15 minutes on micros...

متن کامل

Investigation on effect of holding time in brazing of steel to cemented carbide using Cu-Ag alloy filler metal

Nowadays, cemented carbides-steels joints by brazing method are taken into consideration. One of the problems of these joints is the creation residual stresses that can reduce it with choose correct parameters of brazing. In this study, Silver base alloy filler containing copper, zinc and cadmium have been used in temperature 780°C and the effect of time parameter 5, 10 and 15 minutes on micros...

متن کامل

Temperature Effect on Creep and Fracture Behaviors of Nano-SiO2-composite and AlSi12Cu3Ni2MgFe Aluminum Alloy

In the presented article, the temperature effect was studied on creep properties and fracture behaviors of AlSi12Cu3Ni2MgFe aluminum-silicon alloys, unreinforced and reinforced with SiO2 nano-particles. For such objective, standard specimens were fabricated by gravity casting and stir-casting methods, for aluminum alloys and nano-composites, respectively. Then, force-controlled creep...

متن کامل

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicina oral, patologia oral y cirugia bucal

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2011